Purpose: To compare two solvents for retrieval of lysozyme deposited on a silicone hydrogel (SH) contact lens material galyfilcon A (GA; Acuvue Advance).

Methods: Two buffers used were 50:50 acetonitrile/0.02% trifluoroacetic acid (buffer 1) and 50:50 acetonitrile/50 mM NaOH (buffer 2).

Results: Extraction efficiency from GA lenses was 74% (buffer 1) and 83% (buffer 2). Buffer 2 decreased lysozyme activity > buffer 1. Ex vivo GA lenses showed total protein deposition of 2-16 microg/lens with total lysozyme deposition of 0.3-3.9 microg/lens.

Conclusions: We have developed a low acid strength extraction buffer that can be used to efficiently extract active lysozyme protein from novel siloxane-based contact lens materials.

Download full-text PDF

Source
http://dx.doi.org/10.1080/02713680701830278DOI Listing

Publication Analysis

Top Keywords

silicone hydrogel
8
hydrogel contact
8
contact lens
8
buffer
7
lysozyme
5
conformational quantitative
4
quantitative characterization
4
characterization lysozyme
4
lysozyme extracted
4
extracted galyfilcon
4

Similar Publications

Inspired by counterintuitive water "swelling" ability of the hydrophobic moss of the genus Sphagnum (Peat moss), we prepared a hydrophobic pseudo-hydrogel (HPH), composed of a pure hydrophobic silicone elastomer with a tailored porous structure. In contrast to conventional hydrogels, HPH achieves absorption-induced volume expansion through surface tension induced elastocapillarity, presenting an unexpected absorption-induced volume expansion capability in hydrophobic matrices. We adopt a theoretical framework elucidating the interplay of surface tension induced elastocapillarity, providing insights into the absorption-induced volume expansion behavior.

View Article and Find Full Text PDF

The discharge of oil-laden wastewater from industrial processes and the frequent occurrence of oil spills pose severe threats to the ecological environment and human health. Membrane materials with special wettability have garnered attention for their ability to achieve efficient oil-water separation by leveraging the differences in wettability at the oil-water interface. These materials are characterized by their simplicity, energy efficiency, environmental friendliness, and reusability.

View Article and Find Full Text PDF

Low-cost male urogenital simulator for penile implant surgery training: a 3D printing approach.

3D Print Med

January 2025

Department of Surgical & Interventional Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.

Background: Penile implant surgery is the standard surgical treatment for end-stage erectile dysfunction. However, the growing complexity of modern high-tech penile prostheses has increased the demand for more practical training opportunities. The most advanced contemporary training methods involve simulation training using cadavers, with costs exceeding $5,000 per cadaver, inclusive of biohazard fees.

View Article and Find Full Text PDF

Quarter of a century of contact lens prescribing trends in Australia (2000-2024).

Clin Exp Optom

January 2025

Eurolens Research, Division of Pharmacy and Optometry, The University of Manchester, Manchester, UK.

Clinical Relevance: Knowledge of contact lens prescribing trends can (a) assist practitioners to benchmark their own prescribing habits, (b) help the contact lens industry understand preferred products, and (c) support academics in scholarly writings.

Background: This work aims to document contact lens prescribing trends in Australia over the past quarter of a century.

Methods: An annual survey of contact lens prescribing trends was conducted in Australia each year from 2000 to 2024, inclusive, by asking optometrists to provide information relating to 10 consecutive contact lens fits undertaken between January and March.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!