Imaging with visible light today uses numerous contrast mechanisms, including bright- and dark-field contrast, phase-contrast schemes and confocal and fluorescence-based methods. X-ray imaging, on the other hand, has only recently seen the development of an analogous variety of contrast modalities. Although X-ray phase-contrast imaging could successfully be implemented at a relatively early stage with several techniques, dark-field imaging, or more generally scattering-based imaging, with hard X-rays and good signal-to-noise ratio, in practice still remains a challenging task even at highly brilliant synchrotron sources. In this letter, we report a new approach on the basis of a grating interferometer that can efficiently yield dark-field scatter images of high quality, even with conventional X-ray tube sources. Because the image contrast is formed through the mechanism of small-angle scattering, it provides complementary and otherwise inaccessible structural information about the specimen at the micrometre and submicrometre length scale. Our approach is fully compatible with conventional transmission radiography and a recently developed hard-X-ray phase-contrast imaging scheme. Applications to X-ray medical imaging, industrial non-destructive testing and security screening are discussed.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1038/nmat2096 | DOI Listing |
Pediatr Cardiol
January 2025
Department of Cardiovascular Radiology & Endovascular Interventions, All India Institute of Medical Sciences, New Delhi, 110029, India.
We sought to evaluate the intracardiac morphology and associated cardiovascular anomalies in patients with double inlet right ventricle (DIRV) on multidetector CT angiography. A retrospective search of our departmental database was conducted from January 2014 to January 2023 to identify patients with a diagnosis of DIRV on CT angiography. The intracardiac anatomy and associated cardiovascular abnormalities were systematically evaluated.
View Article and Find Full Text PDFCJEM
January 2025
Department of Emergency Medicine, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität Zu Berlin, Campus Benjamin Franklin, 12203, Berlin, Germany.
J Hand Surg Am
January 2025
Hand and Upper Extremity Division of Plastic and Reconstructive Surgery, University of California Davis, Sacramento, CA.
Purpose: Current technologies to define the zone of acute peripheral nerve injury intraoperatively are limited by surgical experience, time, cumbersome electrodiagnostic equipment, and interpreter reliability. In this pilot study, we evaluated a real-time, label-free optical technique for intraoperative nerve injury imaging. We hypothesize that fluorescence lifetime imaging (FLIm) will detect a difference between the time-resolved fluorescence signatures for acute crush injuries versus uninjured segments of peripheral nerves in sheep.
View Article and Find Full Text PDFAm J Sports Med
January 2025
Department of Orthopaedic Surgery, Washington University School of Medicine, St. Louis, Missouri, USA.
Background: Knee injuries resulting in purely cartilaginous defects are rare, and controversy remains regarding the reliability of chondral-only fixation.
Purpose: To systematically review the literature for fixation methods and outcomes after primary fixation of chondral-only defects within the knee.
Study Design: Systematic review; Level of evidence, 5.
Am J Sports Med
January 2025
Department of Orthopaedic Surgery, Samsung Medical Center, School of Medicine, Sungkyunkwan University, Seoul, South Korea.
Background: Studies are still limited on the isolated effect of retear after arthroscopic rotator cuff repair (ARCR) on functional outcomes after the midterm period.
Purpose: To assess the effect of retear at midterm follow-up after ARCR and to identify factors associated with the need for revision surgery.
Study Design: Cohort study; Level of evidence, 3.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!