Automatic model selection for the 'best localization' of cardiac sources.

Int J Card Imaging

Dipartimento di Fisica, Politecnico di Torino, Italy.

Published: August 1992

AI Article Synopsis

  • The paper discusses a simulation study examining how noise and source models impact the accuracy of biomagnetic field source localization.
  • The authors used statistical analysis (F test) on different localization results to identify an effective 'best localization' method that can automatically select the appropriate source model for specific field distributions.
  • The application of this method to cardiac sources from isolated rabbit hearts showed significant improvements in localization accuracy compared to using a single source model across different field maps.

Article Abstract

In the present paper a simulation study on the influence of noise and source model on the accuracy of localization of the sources of biomagnetic fields is presented. Applying a statistical analysis (F test) to the localization results obtained by various models on the simulated maps calculated using different theoretical sources and different noise levels we were able to define a 'best localization' (BL) method. It allows an automatic determination of the particular source model able to represent in the best statistical way a specific field distribution obtaining the best source localization for that distribution. We applied this method to the localization of cardiac sources in the experimental maps of the magnetic field produced by isolated rabbit hearts completely immersed in a conductive medium. The results clearly indicate that the proposed method is very effective in determining the 'best localization' for every particular field distribution while the use of the same source model for every field map often produces a source localization completely in contrast with the position of cardiac structures of the isolated hearts.

Download full-text PDF

Source
http://dx.doi.org/10.1007/BF01797751DOI Listing

Publication Analysis

Top Keywords

'best localization'
12
source model
12
cardiac sources
8
field distribution
8
source localization
8
source
5
localization
5
automatic model
4
model selection
4
selection 'best
4

Similar Publications

Purpose: We hypothesised that applying radiomics to [F]PSMA-1007 PET/CT images could help distinguish Unspecific Bone Uptakes (UBUs) from bone metastases in prostate cancer (PCa) patients. We compared the performance of radiomic features to human visual interpretation.

Materials And Methods: We retrospectively analysed 102 hormone-sensitive PCa patients who underwent [F]PSMA-1007 PET/CT and exhibited at least one focal bone uptake with known clinical follow-up (reference standard).

View Article and Find Full Text PDF

Terminal metal-phosphorus (M-P) complexes are of significant contemporary interest as potential platforms for P-atom transfer (PAT) chemistry. Decarbonylation of metal-phosphaethynolate (M-PCO) complexes has emerged as a general synthetic approach to terminal M-P complexes. M-P complexes that are stabilized by strong M-P multiple bonds are kinetically persistent and isolable.

View Article and Find Full Text PDF

Topological edge states (TESs) and topological corner states (TCSs) in photonic crystals (PCs) provide an effective way to control the propagation and localization of light. The topological performance of integrated photonic devices can be improved by introducing the basic structural unit of photonic quasicrystals (PQCs) into PCs. However, the previous works arranged the basic structural unit of Stampfli-type and 12-fold Penrose-type photonic quasicrystals into triangular lattices, which have a complex structure and allow light to only propagate around 60° or 120° corners, limiting their applications.

View Article and Find Full Text PDF

Objective: To evaluate the accuracy of the defining characteristics of the nursing diagnosis Impaired skin integrity (00046) in patients admitted to intensive care units (ICUs).

Methods: A cross-sectional diagnostic accuracy study was conducted with 105 adult patients admitted to an ICU. A latent class model with random effects was used to test the sensitivity and specificity of the defining characteristics investigated.

View Article and Find Full Text PDF

Background: Dissemination initiatives have the potential to increase consumer knowledge of and engagement with evidence-based treatments (e.g., cognitive behavioral therapy [CBT]).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!