Efficient electrotransfection into canine muscle.

Technol Cancer Res Treat

University of Ljubljana, Veterinary Faculty Ljubljana, Gerbiceva 60, SI-1000 Ljubljana, Slovenia.

Published: February 2008

Two different types of electroporation protocols have been developed for efficient electrotransfer of plasmid DNA into skeletal muscle of experimental animals. At first, only low voltage electric pulses have been used, but lately, a combination of high and low voltage pulses has been suggested as more efficient. Up to date, in dogs, this type of electroporation protocol has never been used for muscle targeted plasmid DNA electrotransfection. In this study, we used two different DNA plasmids, one encoding green fluorescent protein and one encoding human interleukin-12. Five different electroporation protocols were evaluated. Three of them featured different combinations of high and low voltage pulses, and two were performed with delivery of low voltage pulses only. Our study shows that combination of 1 high voltage pulse (600 V/cm, 100 mus), followed by 4 low voltage pulses (80 V/cm, 100 ms, 1 Hz) yielded in the same transfection efficiency as the standard trains of low voltage pulses. However, this protocol is performed quicker and, thus, more suitable for potential use in clinical practice. In addition, it yielded in detectable systemic expression of human interleukin-12. Electrotransfer of either of the plasmids was associated with only mild and transitory local side effects, without clinically detectable systemic side effects. The results indicate that electrotransfection is a feasible, effective, and safe method for muscle targeted gene therapy in dogs, which could have potential for clinical applications in veterinary medicine of small animals.

Download full-text PDF

Source
http://dx.doi.org/10.1177/153303460800700106DOI Listing

Publication Analysis

Top Keywords

low voltage
24
voltage pulses
20
electroporation protocols
8
plasmid dna
8
combination high
8
high low
8
muscle targeted
8
human interleukin-12
8
v/cm 100
8
potential clinical
8

Similar Publications

Capillary vibrating sharp-edge spray ionization (cVSSI) has been used to control the droplet charging of nebulized microdroplets and monitor effects on protein ion conformation makeup as determined by mass spectrometry (MS). Here it is observed that the application of voltage results in noticeable differences to the charge state distributions (CSDs) of ubiquitin ions. The data can be described most generally in three distinct voltage regions: Under low-voltage conditions (<+200 V, LV regime), low charge states (2+ to 4+ ions) dominate the mass spectra.

View Article and Find Full Text PDF

Organic compounds present promising options for sustainable zinc battery electrodes. Nevertheless, the electrochemical properties of current organic electrodes still lag behind those of their inorganic counterparts. In this study, nitro groups were incorporated into pyrene-4, 5, 9, 10-tetraone (PTO), resulting in an elevated discharge voltage due to their strong electron-withdrawing capabilities.

View Article and Find Full Text PDF

Use of Resonant Acoustic Fields as Atmospheric-Pressure Ion Gates.

Anal Chem

January 2025

Department of Chemistry and Chemical Biology, Rensselaer Polytechnic Institute, Troy, New York 12180, United States.

Ion optics are crucial for spectrometric methods such as mass spectrometry (MS) and ion mobility spectrometry (IMS). Among the wide selection of ion optics, temporal ion gates are of particular importance for time-of-flight MS (TOF-MS) and drift-tube IMS. Commonly implemented as electrostatic ion gates, these optics offer a rapid, efficient means to block ion beams and form discrete ion packets for subsequent analysis.

View Article and Find Full Text PDF

Chirp modulation can generate a relatively flat electro-optic frequency comb (EO comb) and offers the advantage of frequency reconfigurability, demonstrating significant potential in high-precision sensing and absorption spectroscopy measurements. However, nonresonant devices such as waveguides are susceptible to limitations in modulation efficiency and bandwidth during electro-optic modulation. In this paper, by utilizing chirp modulation resonance mode, we have realized an EO comb based on a lithium niobate resonator with small tooth spacing and high flatness.

View Article and Find Full Text PDF

This work proposes a large aperture liquid crystal lens array based on a novel layered combined electrode (LCE) structure. A large aperture (800µm) is achieved by strategically positioning pixel electrodes on either side of the LC lens and auxiliary electrodes at its center. This design effectively doubles the LC lens aperture compared to conventional structures, achieving this at a significantly lower voltage.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!