The Monte Carlo (MC) method has been shown through many research studies to calculate accurate dose distributions for clinical radiotherapy, particularly in heterogeneous patient tissues where the effects of electron transport cannot be accurately handled with conventional, deterministic dose algorithms. Despite its proven accuracy and the potential for improved dose distributions to influence treatment outcomes, the long calculation times previously associated with MC simulation rendered this method impractical for routine clinical treatment planning. However, the development of faster codes optimized for radiotherapy calculations and improvements in computer processor technology have substantially reduced calculation times to, in some instances, within minutes on a single processor. These advances have motivated several major treatment planning system vendors to embark upon the path of MC techniques. Several commercial vendors have already released or are currently in the process of releasing MC algorithms for photon and/or electron beam treatment planning. Consequently, the accessibility and use of MC treatment planning algorithms may well become widespread in the radiotherapy community. With MC simulation, dose is computed stochastically using first principles; this method is therefore quite different from conventional dose algorithms. Issues such as statistical uncertainties, the use of variance reduction techniques, the ability to account for geometric details in the accelerator treatment head simulation, and other features, are all unique components of a MC treatment planning algorithm. Successful implementation by the clinical physicist of such a system will require an understanding of the basic principles of MC techniques. The purpose of this report, while providing education and review on the use of MC simulation in radiotherapy planning, is to set out, for both users and developers, the salient issues associated with clinical implementation and experimental verification of MC dose algorithms. As the MC method is an emerging technology, this report is not meant to be prescriptive. Rather, it is intended as a preliminary report to review the tenets of the MC method and to provide the framework upon which to build a comprehensive program for commissioning and routine quality assurance of MC-based treatment planning systems.

Download full-text PDF

Source
http://dx.doi.org/10.1118/1.2795842DOI Listing

Publication Analysis

Top Keywords

treatment planning
28
dose algorithms
12
treatment
9
issues associated
8
associated clinical
8
clinical implementation
8
beam treatment
8
planning
8
dose distributions
8
calculation times
8

Similar Publications

This scoping review summarizes two emerging electrical impedance technologies: electrical impedance myography (EIM) and electrical impedance tomography (EIT). These methods involve injecting a current into tissue and recording the response at different frequencies to understand tissue properties. The review discusses basic methods and trends, particularly the use of electrodes: EIM uses electrodes for either injection or recording, while EIT uses them for both.

View Article and Find Full Text PDF

Background: Many patients who get discharged from the intensive care unit experience physical dysfunction that persists even after discharge. Physical dysfunction is associated with skeletal muscle atrophy and accompanying intensive care unit-acquired weakness in the early stages of intensive care unit admission, and early diagnosis and prevention with early mobilization are crucial. However, the amount of physical activity required for early mobilization remains controversial in critically ill patients.

View Article and Find Full Text PDF

Background: This study investigates the impact of convergence mode (CM) in Eclipse (Varian Medical Systems) on the quality and complexity of volumetric modulated arc therapy (VMAT) plans for nasopharyngeal carcinoma (NPC) patients.

Methods: We retrospectively analyzed data from 21 NPC patients. For each patient, three VMAT plans with different CM settings (Off, On, and Extended) were created using identical optimization objectives.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to investigate the dosiomics features of the interplay between CT density and dose distribution in lung SBRT plans, and to develop a model to predict treatment failure following lung SBRT treatment.

Methods: A retrospective study was conducted involving 179 lung cancer patients treated with SBRT at the University of Nebraska Medical Center (UNMC) between October 2007 and June 2022. Features from the CT image, Biological Effective Dose (BED) and five interaction matrices between CT and BED were extracted using radiomics mathematics.

View Article and Find Full Text PDF

With this short communication, which contains a new case report on diabetic ulcer, we summarize our research progress in treating several complex conditions at a point where currently available treatments were failing to help the affected patients. We review the first case of lower back pain due to severe spondylitis (T12-L1) treated with intravenous injections of a sterile fraction of human purified amniotic fluid (ViX001) obtained from thoroughly screened volunteers at the time of planned c-section at the term of normal pregnancies. Then, we review the first case of recalcitrant diabetic ulcer treated successfully by twice-daily applications of ViX001 directly on the wound and describe another case of diabetic ulcer treated successfully with ViX001.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!