A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Minimum 10-year survival of Kerboull cemented stems according to surface finish. | LitMetric

Minimum 10-year survival of Kerboull cemented stems according to surface finish.

Clin Orthop Relat Res

Clinical Orthopaedic Research Centre and the Department of Reconstructive and Orthopaedic Surgery, Université René Descartes (Paris 5), Hôpital Cochin (AP-HP), Paris, France.

Published: February 2008

Unlabelled: The optimal surface finish for a cemented THA stem is still debated. We hypothesized surface finish would influence survival of Kerboull cemented hip arthroplasties and a matte finish would have lower survival. We reviewed survival of 433 total hip arthroplasties in 395 patients: 284 consecutive patients (310 hips) were enrolled in a prospective, randomized study of polished (165 hips) or matte finish stems (145 hips) and compared to a historical series of satin stems (123 hips) in 111 patients. The satin and matte finish implants had similar geometry but the polished was quadrangular rather than oval. Finish roughnesses were: polished (radius, 0.04 microm), satin (radius, 0.9 microm), and matte (radius, 1.7 microm). The mean age of the patients at the time of the index arthroplasty was 63.6 years. The survival rate at 13 years, using radiographic loosening as the end point, was 97.3%+/-2.6% for polished stems, 97.1%+/-2.1% for satin stems, and 78.9%+/-5.8% for matte stems. The data suggest survival of Kerboull stems was higher with a polished or satin surface finish than with a matte finish.

Level Of Evidence: Level II, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2505154PMC
http://dx.doi.org/10.1007/s11999-007-0074-6DOI Listing

Publication Analysis

Top Keywords

surface finish
16
survival kerboull
12
matte finish
12
kerboull cemented
8
finish
8
hip arthroplasties
8
satin stems
8
radius microm
8
stems
7
survival
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!