Optical performance results are reported for a molded-glass biaspheric lens. The 6-mm optical diam lens is intended for use in a laser-based optical disk application. The design with fabrication tolerances has an expected on-axis transmitted wave-front performance of 0.06-wave rms optical path difference (OPD) when tested at 0.6328 ,4m and a numerical aperture of 0.45. Transmitted wave-front aberrations were measured on actual molded lenses using a heterodyne interferometer. Typical performance was 0.05-0.08-wave rms- OPD. Experimental results involving mold rotation indicate that lens performance is primarily limited by a surface figure accuracy of one of the molds.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/ao.22.002413 | DOI Listing |
Chem Commun (Camb)
January 2025
College of Electronic and Optical Engineering & College of Flexible Electronics (Future Technology), State Key Laboratory of Organic Electronics and Information Displays, Nanjing University of Posts & Telecommunications (NJUPT), Nanjing, 210023, China.
Traditional sensors struggle in complex human environments, particularly with humidity and strain detection requiring high sensitivity and robust anti-interference. This work introduces a flexible, miniaturized, low-cost dual-mode sensor that combines a novel resonator structure with a chemically modified conducting polymer, enabling simultaneous strain and humidity detection alongside high anti-interference performance sensitivity and wireless transmission.
View Article and Find Full Text PDFThe primary aim of this descriptive cross-sectional study was to examine the relationship between ocular motility and motor skills in school-age children. Participants included 142 schoolchildren (mean age: 7.08 ± 0.
View Article and Find Full Text PDFCureus
December 2024
Emergency, Royal Victorian Eye and Ear Hospital, Melbourne, AUS.
Idiopathic intracranial hypertension (IIH) is a neurological disorder characterized by chronic headaches, cognitive difficulties, reduced quality of life, and rarely irreversible visual loss. Community diagnosis is often challenging due to unfamiliarity with current guidelines and a lack of clinical experience, leading to misdiagnosis and treatment delays, which can negatively impact visual recovery and quality of life. Our study examined the time to diagnosis and investigated the barriers to timely diagnosis in adults with newly diagnosed IIH.
View Article and Find Full Text PDFAm J Ophthalmol Case Rep
March 2025
Department of Ophthalmology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka, 565-0871, Japan.
Purpose: To report a case of bilateral choroidal osteoma successfully treated with subscleral sclerectomy for secondary serous retinal detachment (SRD).
Observations: A 52-year-old Japanese woman first diagnosed with Vogt-Koyanagi-Harada disease and treated with steroids for 9 years was referred to our clinic. SRD in both eyes recurred frequently and was uncontrolled with adalimumab subcutaneous injections and oral cyclosporine, in addition to steroids.
Clin Transl Radiat Oncol
March 2025
Department of Molecular Genetics, Oncode Institute, Erasmus MC Cancer Institute, Erasmus University Medical Center, Rotterdam, the Netherlands.
Background And Purpose: Understanding the cellular and molecular effect of proton radiation, particularly the increased DNA damage complexity at the distal end of the Bragg curve, is current topic of investigation. This work aims to study clonogenic survival and DNA damage foci kinetics of a head and neck squamous cell carcinoma cell line at various positions along a double passively scattered Bragg curve. Complementary studies are conducted to gain insights into the link between cell survival variations, experimentally yielded foci and the number and complexity of double strand breaks (DSBs).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!