Ingested and biomineralized magnetic material in the prey Neocapritermes opacus termite: FMR characterization.

J Magn Reson

Coordenação de Física Aplicada Departamento, Centro Brasileiro de Pesquisas Físicas, R. Xavier Sigaud, 150, Rio de Janeiro 22290-180, Brazil.

Published: March 2008

The temperature dependence of Ferromagnetic Resonance spectra, from 5K to 280K, was used to study the magnetic material present in Neocapritermes opacus termite, the only prey of the Pachycondyla marginata ant. The analysis of the resonant field and peak-to-peak linewidth allowed estimating the particle diameters and the effective anisotropy energy density, K(EFF), as a sum of the bulk and surface contributions. It allowed to magnetically distinguish the particles of termites as collected in field from those of termites after 3 days under a cellulose diet, introduced to eliminate ingested/digested material. The data also, suggest the presence of oriented magnetite nanoparticles with diameters of 11.6+/-0.3nm in termites as collected in field and (14.0+/-0.4nm) in that under a cellulose diet. Differences between their K(EFF) and its components are also observed. Two transitions are revealed in the resonant field temperature dependence, one at about 50K that was associated to surface effects and the other at about 100K attributed to the Verwey transition.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jmr.2007.12.006DOI Listing

Publication Analysis

Top Keywords

magnetic material
8
neocapritermes opacus
8
opacus termite
8
temperature dependence
8
resonant field
8
termites collected
8
collected field
8
cellulose diet
8
ingested biomineralized
4
biomineralized magnetic
4

Similar Publications

RIDME Spectroscopy: New Topics Beyond the Determination of Electron Spin-Spin Distances.

J Phys Chem Lett

January 2025

Department of Chemistry and Applied Biosciences, ETH Zurich, Vladimir Prelog Weg 2, 8093 Zurich, Switzerland.

Relaxation-induced dipolar modulation enhancement (RIDME) is a pulse EPR experiment originally designed to determine distances between spin labels. However, RIDME has several features that make it an efficient tool in a number of "nonconventional" applications, away from the original purpose of this pulse experiment. RIDME appears to be an interesting experiment to probe longitudinal electron spin dynamics, e.

View Article and Find Full Text PDF

Diagnostic imaging of Bacillus cereus brain infection in newborns.

Pediatr Radiol

January 2025

Pediatric Radiology Department, CHRU of Tours, Clocheville Hospital, 49 Boulevard Beranger, 37000, Tours, France.

Background: Cerebral infection with the opportunistic pathogen Bacillus cereus can lead to severe lesions, especially in premature newborns. Early diagnosis would be highly beneficial. The aim of this study was to describe the imaging findings associated with B.

View Article and Find Full Text PDF

Background: Splenic stiffness is a potential imaging marker of portal hypertension. Normative spleen stiffness values are needed to define diagnostic thresholds.

Objective: To report stiffness measurements of the spleen in healthy children undergoing liver magnetic resonance (MR) elastography across MRI vendors and field strengths.

View Article and Find Full Text PDF

Spin Hall nano-oscillators convert DC to magnetic auto-oscillations in the microwave regime. Current research on these devices is dedicated to creating next-generation energy-efficient hardware for communication technologies. Despite intensive research on magnetic auto-oscillations within the past decade, the nanoscale mapping of those dynamics remained a challenge.

View Article and Find Full Text PDF

Objectives: Evaluating the impact of an AI-based automated cardiac MRI (CMR) planning software on procedure errors and scan times compared to manual planning alone.

Material And Methods: Consecutive patients undergoing non-stress CMR were prospectively enrolled at a single center (August 2023-February 2024) and randomized into manual, or automated scan execution using prototype software. Patients with pacemakers, targeted indications, or inability to consent were excluded.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!