In order to satisfy the need of a tool for assessing the treatment of patients with degenerative lumbar spinal stenosis, an evaluation was made of the reliability, construct validity, and responsiveness of the Norwegian version of Spinal Stenosis Measure (SSM, original by Stucki)). This study was a part of a prospective, cohort study. About 75 patients referred for surgery for spinal stenosis participated in the study. A subsample of 30 patients answered the questionnaire twice, test and retest, with at least one week in between. The SSM was translated according to the Guillemin criteria. Reliability was assessed by Bland and Altman's repeatability, intraclass correlation coefficient (ICC) and the coefficient of variance (CV). Internal consistency was assessed by Cronbach's alpha. Construct validity was analysed by correlation analyses. Responsiveness was calculated by the effect size. The reliability between test and retest scores was good for all three subscales of SSM as the ICC-values were above 0.9 and the CVs were below 15%. Cronbach's alpha was above 0.8. The correlation analyses showed high correlation between scales that assessed the same construct, and low to moderate correlation between scales that assessed different constructs. Large effect sizes were found in all the SSM subscales with effect sizes > or =1.2. The Norwegian SSM version has added a highly useful tool for assessing the disease specific status and outcome after treatment in patients who suffer from degenerative lumbar spinal stenosis.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2270389 | PMC |
http://dx.doi.org/10.1007/s00586-007-0576-7 | DOI Listing |
J Orthop Surg Res
January 2025
Center of Medical Genetics, West China Second University Hospital, Sichuan University, Chengdu, Sichuan, 610041, China.
Background: Delta large-channel endoscopy and unilateral biportal endoscopy (UBE) are prominent minimally invasive techniques for treating lumbar spinal stenosis, known for minimal tissue damage, clear visualization, and quick recovery. However, rigorous controlled research comparing these procedures is scarce, necessitating further investigation into their respective complications and long-term effectiveness. This randomized controlled trial aims to compare their perioperative outcomes, focusing on postoperative recovery and complications over time.
View Article and Find Full Text PDFCell Mol Biol Lett
January 2025
Department of Orthopaedics, Peking University Third Hospital, Peking University, No.49 NorthGarden Road, Haidian District, Beijing, 100191, Beijing, China.
Background: Epigenetic modifications have been proved to play important roles in the spinal degenerative diseases. As a type of noncoding RNA, the microRNA (miRNA) is a vital class of regulatory factor in the epigenetic modifications, while the role of miRNAs in the regulation of epigenetic modifications in ligamentum flavum hypertrophy (LFH) has not been fully investigated.
Methods: The miRNA sequencing analysis was used to explore the change of miRNA expression during the fibrosis of ligamentum flavum (LF) cells caused by the TGF-β1 (10 ng/ml).
In Vivo
December 2024
Department of Health and Care Professions, Faculty of Health and Life Sciences, University of Exeter, Exeter, U.K.;
Background/aim: Transient ischaemic attack (TIA) is characterised by a temporary neurological dysfunction resulting from focal ischaemia in the brain, spinal cord or retina without acute infarction. These episodes typically last less than 24 hours and are significant predictors of subsequent ischaemic strokes. Hypertension is a major risk factor for cerebrovascular events, and primary aldosteronism (PA) is recognised as a common cause of secondary hypertension.
View Article and Find Full Text PDFFront Cardiovasc Med
December 2024
Division of Hematology-Oncology, Department of Medicine, Tufts Medical Center, Boston, MA, United States.
Background: A 63-year-old Black woman presented with progressive exertional dyspnea and chronic lower back pain. The course and findings in her case are instructive.
Case Report: Family history was notable for cardiac deaths.
Indian J Orthop
January 2025
Department of Orthopaedic Surgery, Hillel Yaffe M.C., 3100 Hadera, Israel.
Objective: To present the clinical result of spinal fixation system made entirely of Carbon-Fiber-Reinforced (CFR)-Hybrid Polyaryl-Ether-Ether-Ketone (PEEK).
Summary Of Background Data: Fusion surgery has been used to treat chronic low back pain caused by degenerative disk disease (DDD). The traditional pedicle screw system made of titanium, though biocompatible, can lead to complications, such as stress shielding and implant failure.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!