Short segment pedicle screw instrumentation and augmentation vertebroplasty in lumbar burst fractures: an experience.

Eur Spine J

Spine Clinic, House No. 60, Haider Colony, Soura, Srinagar, Kashmir, 190011, India.

Published: March 2008

To assess the efficacy and feasibility of vertebroplasty and posterior short-segment pedicle screw fixation for the treatment of traumatic lumbar burst fractures. Short-segment pedicle screw instrumentation is a well described technique to reduce and stabilize thoracic and lumbar spine fractures. It is relatively a easy procedure but can only indirectly reduce a fractured vertebral body, and the means of augmenting the anterior column are limited. Hardware failure and a loss of reduction are recognized complications caused by insufficient anterior column support. Patients with traumatic lumbar burst fractures without neurologic deficits were included. After a short segment posterior reduction and fixation, bilateral transpedicular reduction of the endplate was performed using a balloon, and polymethyl methacrylate cement was injected. Pre-operative and post-operative central and anterior heights were assessed with radiographs and MRI. Sixteen patients underwent this procedure, and a substantial reduction of the endplates could be achieved with the technique. All patients recovered uneventfully, and the neurologic examination revealed no deficits. The post-operative radiographs and magnetic resonance images demonstrated a good fracture reduction and filling of the bone defect without unwarranted bone displacement. The central and anterior height of the vertebral body could be restored to 72 and 82% of the estimated intact height, respectively. Complications were cement leakage in three cases without clinical implications and one superficial wound infection. Posterior short-segment pedicle fixation in conjunction with balloon vertebroplasty seems to be a feasible option in the management of lumbar burst fractures, thereby addressing all the three columns through a single approach. Although cement leakage occurred but had no clinical consequences or neurological deficit.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2270394PMC
http://dx.doi.org/10.1007/s00586-008-0587-zDOI Listing

Publication Analysis

Top Keywords

lumbar burst
16
burst fractures
16
pedicle screw
12
short-segment pedicle
12
short segment
8
screw instrumentation
8
posterior short-segment
8
traumatic lumbar
8
vertebral body
8
anterior column
8

Similar Publications

Intradural extramedullary spinal cord tumors are rare but can cause significant neurological symptoms. We present a case of a 23-year-old male who developed progressive bilateral leg pain and lower limb weakness 2 years after undergoing posterior spinal fixation for a T12 burst fracture. Magnetic resonance imaging (MRI) revealed an intradural extramedullary tumor at the site of the previous surgery.

View Article and Find Full Text PDF

Background: Lumbar burst fracture combined with lamina fracture is a special type of spinal fracture. Neither CT nor MRI can accurately determine it. The present study aims to investigate the clinical value of 3D CT/MRI fusion imaging in the treatment of lumbar burst fracture complicated with lamina fracture.

View Article and Find Full Text PDF

The purpose of this study was to present the surgical technique of Unilateral Biportal Endoscopic (UBE) decompression combined with percutaneous pedicle screws for the treatment of thoracolumbar burst fractures with secondary spinal stenosis. Thoracolumbar burst fracture is a common traumatic disease in spinal surgery. In the Arbeitsgemeinschaft für Osteosynthesefragen (AO) classification of thoracolumbar fractures, Type A fractures have the highest incidence, accounting for about 70%, with A1 and A3 types being the most common.

View Article and Find Full Text PDF

Objectives: This study aims to investigate the relationship between the expression of lipid metabolism and cartilage degeneration-related factors and Modic changes (MCs) of lumbar vertebral.

Patients And Methods: This prospective study included a total of 10 patients (6 males, 4 females; mean age: 60.4±8.

View Article and Find Full Text PDF

Lumbar transcutaneous spinal cord stimulation (TSS) evokes synchronized muscle responses, termed spinally evoked motor response (sEMR). Whether the structures TSS activates to evoke sEMRs differ when TSS intensity and waveform are varied is unknown. In 15 participants (9 F, 6 M), sEMRs were evoked by TSS over L1-L3 (at sEMR threshold and suprathreshold intensities) with conventional (one 400-µs biphasic pulse) or high-frequency burst (ten 40-µs biphasic pulses at 10 kHz) stimulus waveforms in vastus medialis (VM), tibialis anterior (TA), and medial gastrocnemius (MG) muscles.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!