Purpose: In clinical routine, attenuation correction (AC) using X-ray CT is a relatively new method for reducing attenuation artefacts. We evaluated the quality of attenuation maps generated with very low tube current to minimise exposure due to transmission scanning.
Methods: SPECT/CT acquisitions were performed with a Millenium VG3 gamma camera with the Hawkeye CT device (GE Medical Systems). In phantom studies, determination of linear absorption coefficients (mu) for air, water and Teflon was carried out. The attenuation maps in both stress and resting studies from 62 patients (21 females and 41 males, age 63.7 +/- 11.0 years, BMI 30.0 +/- 5.7 kg/m(2)) were compared. All patients underwent exercise or pharmacologic stress testing and a resting study for comparison using Tc-99m MIBI or Tc-99m Tetrofosmin. AC in stress studies was performed using 2.5 mA tube current (set as default), whereas 1.0 mA was used in resting studies.
Results: In both phantom and patient studies, differences of linear absorption coefficients were not significant (p > 0.05). Effective dose decreased from 0.90 mSv down to 0.36 mSv, respectively.
Conclusion: Our results indicate that reliable attenuation maps (mu-maps) of the thorax can be obtained even with the use of very low tube current. In our study, radiation exposure in CT-based AC for myocardial perfusion SPECT was substantially lowered (60% reduction). This is of particular importance in high-risk patients who may have to undergo follow-up scans and in research studies on volunteers. The procedure introduced is relatively simple and can be transferred to other SPECT/CT devices, which allow adjustment of tube current.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00259-007-0680-2 | DOI Listing |
Curr Nutr Rep
January 2025
City University of New York Graduate School of Public Health and Health Policy, 55 West 125th Street, New York, NY, 10027, USA.
Purpose Of Review: Nutition has long been of importance in the care of Huntington's disease (HD). The purpose of this review is to summarize recent research relevant to HD nutrition, and to describe some emerging theoretical approaches to research in this area.
Recent Findings: Clinical studies have identified swallowing problems and fear of choking as major impediments to maintaining nutritional status with HD.
Arch Argent Pediatr
January 2025
Hospital Italiano de Buenos Aires, City of Buenos Aires, Argentina.
Introduction. Middle-ear ventilation tubes are commonly placed in pediatric patients because of the high frequency of otitis media. Although avoidance of water activity has been recommended to prevent otorrhea, studies indicate that exposure to water does not increase these episodes.
View Article and Find Full Text PDFAnn Ital Chir
January 2025
Division of Thoracic Surgery, McMaster University, Hamilton, ON L8S 4L8, Canada.
Aim: Timing of chest tube removal post lung resection is variable in practice and often based on personal experience rather than evidence. The current practice in chest tube management among thoracic surgeons across Canada is so far unknown. Our primary aim was to assess the current status of chest tube removal in Canada in order to uncover potential shortcomings.
View Article and Find Full Text PDFSyst Rev
January 2025
Department of Neurosurgery, Pingxiang People's Hospital, Pingxiang, Jiangxi Province, 337000, China.
Background: A systematic appraisal of the comparative efficacy and safety profiles of naso-intestinal tube versus gastric tube feeding in the context of enteral nutrition for mechanically ventilated (MV) patients is imperative. Such an evaluation is essential to inform clinical practice, ensuring that the chosen method of nutritional support is both optimal and safe for this patient population.
Methods: We executed an exhaustive search across PubMed et al.
ACS Nano
January 2025
Shenzhen Key Laboratory of Smart Healthcare Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Department of Biomedical Engineering, Southern University of Science and Technology, No. 1088 Xueyuan Road, Nanshan District, Shenzhen, Guangdong 518055, PR China.
Extracellular matrix (ECM)-based small-diameter vascular grafts (SDVGs, inner diameter (ID) < 6 mm) hold great promise for clinical applications. However, existing ECM-based SDVGs suffer from limited donor availability, complex purification, high cost, and insufficient mechanical properties. SDVGs with ECM-like structure and function, and good mechanical properties were rapidly prepared by optimizing common materials and preparation, which can improve their clinical prospects.