MRI at high magnetic fields (> 3.0 T ) is complicated by strong inhomogeneous radio-frequency fields, sometimes termed the "bias field". These lead to nonuniformity of image intensity, greatly complicating further analysis such as registration and segmentation. Existing methods for bias field correction are effective for 1.5 T or 3.0 T MRI, but are not completely satisfactory for higher field data. This paper develops an effective bias field correction for high field MRI based on the assumption that the nonuniformity is smoothly varying in space. Also, nonuniformity is quantified and unmixed using high order neighborhood statistics of intensity cooccurrences. They are computed within spherical windows of limited size over the entire image. The restoration is iterative and makes use of a novel stable stopping criterion that depends on the scaled entropy of the cooccurrence statistics, which is a non monotonic function of the iterations; the Shannon entropy of the cooccurrence statistics normalized to the effective dynamic range of the image. The algorithm restores whole head data, is robust to intense nonuniformities present in high field acquisitions, and is robust to variations in anatomy. This algorithm significantly improves bias field correction in comparison to N3 on phantom 1.5 T head data and high field 4 T human head data.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2194598PMC
http://dx.doi.org/10.1117/12.711533DOI Listing

Publication Analysis

Top Keywords

bias field
12
field correction
12
high field
12
head data
12
field
8
nonuniformities high
8
high order
8
order neighborhood
8
neighborhood statistics
8
entropy cooccurrence
8

Similar Publications

Exchange-Biased Fe/FeF Nanocomposites: Unveiling the Structural Insights into Spin-Dependent Tunnel Transport.

ACS Appl Mater Interfaces

December 2024

Frontier Research Institute for Interdisciplinary Sciences, Tohoku University, Sendai 980-8578, Japan.

Spin-dependent charge tunneling transport of magnetic nanocomposites under alternating current or direct current has revolutionized the understanding of the quantum-mechanical phenomenon in complex granular solids. The tunnel magnetodielectric (TMD) and tunnel magnetoresistance (TMR) effects are two critical functionalities in this context, where dielectric permittivity and electrical resistance, respectively, change in response to an applied magnetic field due to charge tunneling. However, the structural correlation between TMD and TMR, as well as the mechanisms, remains poorly understood, largely due to the challenges in directly characterizing nanoscale intergranular interactions.

View Article and Find Full Text PDF

It is widely accepted that mobile ions are responsible for the slow electronic responses observed in metal halide perovskite-based optoelectronic devices, and strongly influence long-term operational stability. Electrical characterisation methods mostly observe complex indirect effects of ions on bulk/interface recombination, struggle to quantify the ion density and mobility, and are typically not able to fully quantify the influence of the ions upon the bulk and interfacial electric fields. We analyse the bias-assisted charge extraction (BACE) method for the case of a screened bulk electric field, and introduce a new characterisation method based on BACE, termed ion drift BACE.

View Article and Find Full Text PDF

Bias Tunable SnS/ReSe Tunneling Photodetector with High Responsivity and Fast Response Speed.

Small

December 2024

School of Microelectronics, Northwestern Polytechnical University, 127 West Youyi Road, Beilin District, Xi'an, Shaanxi, 710072, P. R. China.

2D photodetectors operating in photovoltaic mode exhibit a trade-off between response speed and photoresponsivity. This work presents a phototransistor based on SnS/ReSe heterojunction. Under negative bias, the energy band spike at the heterojunction interface impedes the carrier drifting so that the dark current is as low as 10 A.

View Article and Find Full Text PDF

Reconsidering the usual suspects in age-related hematologic disorders: is stem cell dysfunction a root cause of aging?

Exp Hematol

December 2024

Division of Experimental Hematology, German Cancer Research Center (DKFZ), Heidelberg, Germany; Experimental Hematology Group, Heidelberg Institute for Stem Cell Technology and Experimental Medicine (HI-STEM), Heidelberg, Germany. Electronic address:

Aging exerts a profound impact on the hematopoietic system, leading to increased susceptibility to infections, autoimmune diseases, chronic inflammation, anemia, thrombotic events, and hematologic malignancies. Within the field of experimental hematology, the functional decline of hematopoietic stem cells (HSCs) is often regarded as a primary driver of age-related hematologic conditions. However, aging is clearly a complex multifaceted process involving not only HSCs but also mature blood cells and their interactions with other tissues.

View Article and Find Full Text PDF

We performed a systematic review of the ictal semiology of temporo-frontal seizures with the aim to summarize the state-of-the-art anatomo-clinical correlations in the field, and help guide the interpretation of ictal semiology within the framework of presurgical evaluation. We conducted the systematic review and meta-analysis, and reported its results according to the Preferred Reporting Items for Systematic Review and Meta-Analysis statement. We searched electronic databases (Scopus, PUBMED, Web of Science, and EMBASE) using relevant keywords related to temporal, frontal and sublobar structures, semiology, and electroencephalography/stereoelectroencephalography exploration.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!