Pulmonary oxygen uptake and heart rate kinetics during the six-minute walk test in transplant recipients.

Transplantation

Cardiovascular Therapeutic Exercise Laboratory, Faculty of Rehabilitation Medicine, Alberta Research Centre for Child Health Evidence, Department of Pediatrics, University of Alberta, Edmonton, Alberta, Canada.

Published: January 2008

Background: The effect of organ transplantation on arterial compliance, pulmonary oxygen uptake (VO2p) and heart rate kinetics during the 6-minute walk test (6-MWT) remains unknown.

Methods: Twenty-two thoracic (heart and/or lung) organ transplant recipients (TOTR, 51+/-12 years) and 30 abdominal (kidney, kidney-pancreas, or liver) organ transplant recipients (AOTR, 46+/-11 years) from the 2006 Canadian Transplant Games, and 37 healthy controls (HC) completed a 6-MWT. VO2p, heart rate kinetics, and arterial compliance were determined.

Results: The 6-MWT distance and highest VO2p were significantly lower in TOTR and AOTR versus HC. The highest 6-MWT heart rate was lower in TOTR (11%) and AOTR (13%) versus HC. VO2p kinetics were slower in TOTR (52+/-11 sec, P
Conclusions: TOTR and AOTR have abnormal VO2p kinetics, which is secondary to prolonged heart rate kinetics and impaired vascular function in TOTR, but not AOTR.

Download full-text PDF

Source
http://dx.doi.org/10.1097/01.tp.0000296056.00863.f0DOI Listing

Publication Analysis

Top Keywords

heart rate
16
rate kinetics
12
transplant recipients
12
pulmonary oxygen
8
oxygen uptake
8
walk test
8
arterial compliance
8
vo2p heart
8
organ transplant
8
lower totr
8

Similar Publications

On the causal connection in lifespan correlations and the possible existence of a 'number of life' at molecular level.

Sci Rep

December 2024

Departamento de Astronomía, Universidad de Chile, Casilla 36-D, Santiago, Chile.

Multiple physiological traits correlates with lifespan, being unclear both the causal connection among them and with the process of ageing. In this paper, we show that six traits (such as metabolic rate, mass, heart rate, etc) acting at the system level, are all related to lifespan thru the existence of an approximately constant number of respiration cycles in a lifespan ([Formula: see text]), therefore, we find that those relationships are not independently related to ageing. In addition, we study if the approximately constant [Formula: see text] is possibly linked with the end-of-lifespan somatic mutation burden, another number recently found to be approximately constant (Cagan, Nature 604:517-524, 2022).

View Article and Find Full Text PDF

Effect of heart rate on B-type natriuretic peptide in sinus rhythm.

Sci Rep

December 2024

Division of Cardiology, Department of Internal Medicine, The Jikei University School of Medicine, 3-25-8 Nishi-shimbashi, Minato-ku, Tokyo, 105-8461, Japan.

B-type natriuretic peptide (BNP) levels accurately reflect the degree of cardiac overload in heart failure. Considering cardiac morphology and intracardiac pressure, including the left ventricular end-systolic volume index (LVESVI) and left ventricular end-diastolic volume index (LVEDVI), is essential for cardiac overload assessment. These indexes influence plasma BNP levels, and high heart rate is likely associated with cardiac morphology.

View Article and Find Full Text PDF

Cognitive load (CL) is one of the leading factors moderating states and performance among drivers. Heavily increased CL may contribute to the development of mental stress. Averaged heart rate (HR) and heart rate variability (HRV) indices are shown to reflect CL levels in different tasks.

View Article and Find Full Text PDF

BAY 2413555 is a novel selective and reversible positive allosteric modulator of the type 2 muscarinic acetylcholine (M2) receptor, aimed at enhancing parasympathetic signaling and restoring cardiac autonomic balance for the treatment of heart failure (HF). This study tested the safety, tolerability and pharmacokinetics of this novel therapeutic option. REMOTE-HF was a multicenter, double-blind, randomized, placebo-controlled, phase Ib dose-titration study with two active arms.

View Article and Find Full Text PDF

Background: The new Amplatzer Steerable Delivery Sheath is a delivery system designed to improve ease-of-use and procedural results of left atrial appendage closure (LAAC). We aimed to compare procedural results after switching our LAAC program at a tertiary care center with the Amulet device to the Steerable Delivery Sheath, with a control group of LAAC employing the standard sheath.

Methods: The first n = 32 consecutively treated patients at our site using the Amulet device with the Steerable Delivery Sheath were included in this retrospective analysis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!