A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Characteristics of an absolutely calibrated flat-field extreme ultraviolet spectrometer in the 10-130 A range for fusion plasma diagnostics. | LitMetric

A flat-field extreme ultraviolet (EUV) spectrometer with a nominal 2400 grooves/mm aberration-corrected ruled grating has been developed to analyze the emission spectrum in the wavelength range of 10 to 130 A from large helical device (LHD) plasmas. Spectral properties such as resolution, sensitivity, contribution of higher-order light, and background stray light have been studied using emission spectra mainly from intrinsic impurities, e.g., C and Fe. It is found that the spectrometer well resolves closely existing spectral lines of highly ionized medium- and high-Z impurities even in a very short wavelength range such as 10 to 20 A. As a result, it allows one to study the charge state distribution of elements in high-temperature fusion plasma. The ruled grating was then replaced by a laminar type holographic grating for the comparative study. The spectral resolution for the ruled grating (Dlambda approximately 0.08 A at 33.73 A) is clearly better than the holographic grating (Dlambda approximately 0.13 A at 33.73 A). Both gratings well suppress the higher-order light, e.g., the second-order light is only less than 11% of the first-order light for C vi(33.73 A). Relative sensitivity calibration with the wavelength has been done using bremsstrahlung continuum from the LHD plasmas. Absolute intensity calibration has been done by comparing the spectral intensities directly with the absolutely calibrated 1200 grooves/mm EUV spectrometer in the overlapping range of 90-120 A due to the absence of a good branching pair in 10-130 A. As a typical result on the present spectrometer well-resolved n=2-3 full transition arrays from Ne- to Li-like ions are measured for Fe and Ti and wavelengths of the spectral array are tabulated for each charge state. Spectroscopic comparison is also made between the 1200 grooves/mm and 2400 grooves/mm gratings in a range of 50-130 A.

Download full-text PDF

Source
http://dx.doi.org/10.1364/ao.47.000135DOI Listing

Publication Analysis

Top Keywords

ruled grating
12
absolutely calibrated
8
flat-field extreme
8
extreme ultraviolet
8
fusion plasma
8
euv spectrometer
8
2400 grooves/mm
8
wavelength range
8
lhd plasmas
8
higher-order light
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!