The purpose of this study was to establish a novel imaging system for evaluation of cataract in small animals. Diabetic cataract was induced in male Wistar rats by a combination of a bolus injection of streptozotocin (65 mg/kg, i.v.) and 5% D-glucose given as drinking water. To assess cataract development, we designed a digital camera system equipped with a non-reflecting illuminator for capturing clear high-resolution full lens images in the horizontal plane. Cataract was evaluated from the resulting images using both an observer-based scoring system and quantitative digital image-analysis techniques. The onset of cataract was detected in the peripheral section of the lens in 57% of cases 2 weeks after induction of hyperglycemia. Central opacities were visible following 3 weeks in hyperglycemic conditions. The cataract increased in severity with time, so that by week 9 in hyperglycemic conditions, mature cataracts were developed in over 90% of lenses. Treatment of diabetic rats with GP-1447, an aldose reductase inhibitor, completely prevented the formation of diabetic cataracts. These results indicate that the digital imaging system established in the present study permits an assessment of all stages of cataract development and it is helpful for accurately evaluating the effects of therapeutic drugs on cataracts.

Download full-text PDF

Source
http://dx.doi.org/10.1254/jphs.fp0071500DOI Listing

Publication Analysis

Top Keywords

imaging system
12
digital imaging
8
system evaluation
8
cataract
8
diabetic rats
8
cataract development
8
hyperglycemic conditions
8
system
5
novel high
4
high resolution
4

Similar Publications

Jaundice is an indication of hyperbilirubinemia and is caused by derangements in bilirubin metabolism. It is typically apparent when serum bilirubin levels exceed 3 mg/dL and can indicate serious underlying disease of the liver or biliary tract. A comprehensive medical history, review of systems, and physical examination are essential for differentiating potential causes such as alcoholic liver disease, biliary strictures, choledocholithiasis, drug-induced liver injury, hemolysis, or hepatitis.

View Article and Find Full Text PDF

Objective: Ventricular shunt insertion is a common procedure in pediatric neurosurgical practice. In many areas of medicine there is a push toward rationalization of healthcare resources and a reduction in low-value tests or procedures. The intraoperative sampling of CSF at the time of shunt insertion is one traditional aspect of care that has not been rigorously evaluated.

View Article and Find Full Text PDF

Exploring the Unique Properties and Superior Schwann Cell Guiding Abilities of Spider Egg Sac Silk.

ACS Appl Bio Mater

January 2025

Institute of Physics and Materials Science, Department of Natural Sciences and Sustainable Ressources, BOKU University, Peter Jordan-Straß 82, 1190 Vienna, Austria.

Spider silk (SPSI) is a promising candidate for use as a filler material in nerve guidance conduits (NGCs), facilitating peripheral nerve regeneration by providing a scaffold for Schwann cells (SCs) and axonal growth. However, the specific properties of SPSI that contribute to its regenerative success remain unclear. In this study, the egg sac silk of is investigated, which contains two distinct fiber types: tubuliform (TU) and major ampullate (MA) silk.

View Article and Find Full Text PDF

Sn-based electrodes are promising candidates for next-generation lithium-ion batteries. However, it suffers from deleterious micro-structural deformation as it undergoes drastic volume changes upon lithium insertion and extraction. Progress in designing these materials is limited to complex structures.

View Article and Find Full Text PDF

Objective: This study aimed to introduce and evaluate a novel software-based system, BioTrace, designed for real-time monitoring of thermal ablation tissue damage during image-guided radiofrequency ablation for hepatocellular carcinoma (HCC).

Methods: BioTrace utilizes a proprietary algorithm to analyze the temporo-spatial behavior of thermal gas bubble activity during ablation, as seen in conventional B-mode ultrasound imaging. Its predictive accuracy was assessed by comparing the ablation zones it predicted with those annotated by radiologists using contrast-enhanced computed tomography (CECT) 24 hours post-treatment, considered the gold standard.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!