An aging society is a reality in developed countries. An aging population requires more healthcare workers and facilities. To reduce this social problem, it is worthwhile to develop a wearable computer for elders or patients to watch over them. In this study, we developed a wearable computer, in which accelerometers were installed to detect variations of posture, falls, and gait disability. The advantages of this system include a designated database server in each patient's home, scalability and flexibility to adapt to patient's needs, and full patient access to their own information. As a first step, we adopted this system for healthy young volunteers with or without impediments to validate the system. The results show that this system can successfully detect variations in posture and falls. We also succeeded in real-time automatic gait analysis by using the Hampering Index. The present study gives useful knowledge for the development of a wearable computer to support the care of elders or other patients.

Download full-text PDF

Source
http://dx.doi.org/10.1089/tmj.2007.0015DOI Listing

Publication Analysis

Top Keywords

wearable computer
12
development wearable
8
gait analysis
8
elders patients
8
detect variations
8
variations posture
8
posture falls
8
system
5
wearable surveillance
4
surveillance system
4

Similar Publications

Novel Human Activity Recognition (HAR) methodologies, which are built upon learning algorithms and employ ubiquitous sensors, have achieved remarkable precision in the identification of sports activities. Such progress benefits all age groups of humanity, and in the future, AI will be used to address difficult problems in scientific research. A novel approach is introduced in this article to utilize motion sensor data in order to categorize and distinguish various categories of sports activities.

View Article and Find Full Text PDF

Wearable non-invasive neuroprosthesis for targeted sensory restoration in neuropathy.

Nat Commun

December 2024

Neuroengineering Laboratory, Department of Health Sciences and Technology, ETH Zurich, Zurich, Switzerland.

Peripheral neuropathy (PN), the most common complication of diabetes, leads to sensory loss and associated health issues as pain and increased fall risk. However, present treatments do not counteract sensory loss, but only partially manage its consequences. Electrical neural stimulation holds promise to restore sensations, but its efficacy and benefits in PN damaged nerves are yet unknown.

View Article and Find Full Text PDF

Background: Simultaneous and proportional control (SPC) based on surface electromyographic (sEMG) signals has emerged as a research hotspot in the field of human-machine interaction (HMI). However, the existing continuous motion estimation methods mostly have an average Pearson coefficient (CC) of less than 0.85, while high-precision methods suffer from the problem of long inference time (> 200 ms) and can only estimate SPC of less than 15 hand movements, which limits their applications in HMI.

View Article and Find Full Text PDF

Bio-energy-powered microfluidic devices.

Biomicrofluidics

December 2024

Department of Orthopaedics, Shanghai Key Laboratory for Prevention and Treatment of Bone and Joint Diseases, Shanghai Institute of Traumatology and Orthopaedics, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200025, China.

Bio-microfluidic technologies offer promising applications in diagnostics and therapy, yet they face significant technical challenges, particularly in the need for external power sources, which limits their practicality and user-friendliness. Recent advancements have explored innovative methods utilizing body fluids, motion, and heat to power these devices, addressing the power supply issue effectively. Among these, body-motion and body-heat-powered systems stand out for their potential to create self-sustaining, wearable, and implantable devices.

View Article and Find Full Text PDF

Mechanical failure of medical implants, especially in orthopedic poses a significant burden to the patients and healthcare system. The majority of the implant failures are diagnosed at very late stages and are of mechanical causes. This makes the diagnosis and screening of implant failure very challenging.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!