[Dose and image quality in intraoral radiography].

Tandlaegebladet

Statens Institut for Strålehygiejne, København.

Published: November 1991

The technique factors when performing intraoral X-ray exposures must be selected in such a way that sufficient diagnostic information is obtained at a reasonable patient dose. The Danish National Institute of Radiation Hygiene has performed a study comprising 32 dental X-ray sets. The mean value of the skin dose for a maxillary molar was 9.6 mGy and the value for the dental colleges 7.0 mGy. For a mandibular incisor the corresponding doses were 7.7 mGy and 3.6 mGy. After the conclusion of the mentioned study it has been part of the institute's inspection procedure for dental X-ray sets to measure patient skin doses. 243 measurements were performed and the mean value of the entrance skin dose was 6.5 mGy and the dose interval was 0.7-57 mGy. All doses are normalised to speed class D film. At 16% of the inspected sets films of speed class E were used. The remainder used class D films. The spread in doses cannot be explained by variation in equipment parameters alone but is to a high degree due to a combination of inappropriate film processing and exposure time. Interviews with staff in dental clinics confirm that films are frequently processed until the desired density is obtained by visual estimation. It is shown that the skin dose when using film of speed class D can be kept below 7 mGy for a mandibular incisor. Concluding is stated that film processing shall be performed in accordance with specifications from the manufacturer of the developer. Film of speed class E must be used. Finally must the exposure time be graduated according to the object exposed.

Download full-text PDF

Source

Publication Analysis

Top Keywords

speed class
16
skin dose
12
dental x-ray
8
x-ray sets
8
mgy mandibular
8
mandibular incisor
8
film processing
8
exposure time
8
film speed
8
mgy
7

Similar Publications

Background Orthodontic diagnostic workflows often rely on manual classification and archiving of large volumes of patient images, a process that is both time-consuming and prone to errors such as mislabeling and incomplete documentation. These challenges can compromise treatment accuracy and overall patient care. To address these issues, we propose an artificial intelligence (AI)-driven deep learning framework based on convolutional neural networks (CNNs) to automate the classification and archiving of orthodontic diagnostic images.

View Article and Find Full Text PDF

Riboli, A, Nardi, F, Osti, M, Cefis, M, Tesoro, G, and Mazzoni, S. Training load, official match locomotor demand, and their association in top-class soccer players during a full competitive season. J Strength Cond Res 39(2): 249-259, 2025-To examine training load and official match locomotor demands of top-class soccer players during a full competitive season and to evaluate their association.

View Article and Find Full Text PDF

As people's material living standards continue to improve, the types and quantities of household garbage they generate rapidly increase. Therefore, it is urgent to develop a reasonable and effective method for garbage classification. This is important for resource recycling and environmental improvement and contributes to the sustainable development of production and the economy.

View Article and Find Full Text PDF

Alterations of the extracellular matrix (ECM), including both mechanical (such as stiffening of the ECM) and chemical (such as variation of adhesion proteins and deposition of hyaluronic acid (HA)) changes, in malignant tissues have been shown to mediate tumor progression. To survey how cells from different tissue types respond to various changes in ECM mechanics and composition, we measured physical characteristics (adherent area, shape, cell stiffness, and cell speed) of 25 cancer and 5 non-tumorigenic cell lines on 7 different substrate conditions. Our results indicate substantial heterogeneity in how cell mechanics changes within and across tissue types in response to mechanosensitive and chemosensitive changes in ECM.

View Article and Find Full Text PDF

Application of high-heat input welding on high-tensile strength steels causes deterioration of mechanical properties of the welded joint, due to softening and grain coarsening in the heat-affected zone (HAZ). In this study, low-heat input narrow-gap hot-wire laser welding was applied to 12 mm thick 780 MPa-class high-tensile strength steel plate. Conditions were optimized based on microstructural observations of joints produced at various welding speeds.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!