Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Unlabelled: The present study is a part of a larger project on assessment of exposure to biological agents and respiratory health effects among metal workers.
Objectives: The aim of this study was to evaluate the level of microbial contamination of metalworking coolants as a potential source of harmful biological agents in three different metal industry plants in Poland.
Material And Methods: Ten samples of coolants with a different state of wear, including four fresh fluids, were analyzed. Qualitative and quantitative analysis of bacteria and mould content was performed using standard analytical methods. Bacterial endotoxin concentration was determined by the kinetic, chromogenic version of the LAL test.
Results: The analysis showed the total bacterial counts ranging from 1.0x10(1) CFU/ml to 3.2x10(7) CFU/ml, 60% to 100% of which were Gram-negative bacteria capable of producing endotoxins. Among the highly contaminated coolants, one unused concentrate was also found. The predominant species of bacteria was Shewanella putrefaciens present in 60% of the samples. As for moulds, the predominant species was Acremonium butyri. The average concentration of bacterial endotoxins was 773 EU/ml in the old coolants, and much lower in the fresh fluids 285 EU/ml. A correlation (r=0.66) was found between endotoxin concentration and the number of Gram-negative bacteria detected in the coolants.
Conclusion: Procedures should be developed for cleaning tanks during fluid replacement to minimize the risk of bacterial growth in the coolants and limit bioaerosol emission in workplace. Due to the affinity of microflora for the water phase, it is advisable to use effective biocides with appropriate partition coefficient between the water phase and oil phase.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.2478/v10001-007-0036-y | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!