Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: To investigate whether use of same-size donor and recipient trephines reduced myopia after penetrating keratoplasty for keratoconus.
Design: Retrospective cohort study.
Participants: Eight hundred seventy-eight first grafts for keratoconus were reported to UK Transplant between April 1999 and December 2003. There were 234 and 644 grafts in the same-size and oversize donor trephine groups, respectively. At 1 year, mean spherical equivalent (SE) data were available for 116 eyes (50%) and 295 eyes (46%) in the same-size and oversize groups. At 2 years, mean SE data were available for 64 eyes (27%) and 148 eyes (23%) in the same-size and oversize groups.
Methods: Logistic regression and univariate analysis of follow-up data submitted to UK Transplant.
Main Outcome Measures: At 1 and 2 years postoperatively, mean SE, magnitude of the cylindrical component of the refraction, postoperative uncorrected visual acuity (VA), postoperative best-corrected VA, and postoperative complications were recorded.
Results: The mean SEs for the same-size and oversize donor trephine groups, respectively, were -1.45 diopters (D) and -1.41 D at 1 year (P = 0.6) and -1.74 D and -2.19 D at 2 years postoperatively (P = 0.3). Although there were no differences in graft survival between the groups at 1 and 2 years, there was a higher incidence of postoperative wound leaks in the same-size group (P = 0.03).
Conclusion: Use of same-size donor and recipient trephines did not reduce myopia and was associated with an increased risk of postoperative complications.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ophtha.2007.04.051 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!