The purpose of this study was to investigate glenohumeral translation in-vivo during active shoulder abduction in the scapular plane. Three-dimensional (3D) models of 9 shoulders were created from CT scans. Fluoroscopic views aligned to the plane of the scapula were recorded during active arm abduction with neutral rotation. 3D motions were determined using model-based 3D-to-two-dimensional (2D) registration. Humeral translation was referenced to the glenoid center in the superior/inferior direction. The humerus moved an average of 1.7 mm superior with arm abduction, from an inferior location to the glenoid center. The humeral head was centered within 1 mm from the glenoid center above 80 degrees abduction. Variability in glenohumeral translation between shoulders decreased significantly from initial to final arm abduction. Our findings agree with some authors' observations of inferior-to-central translation of the humerus and behavior as a congruent ball and socket. We believe this information will help improve the understanding of shoulder function.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jse.2007.05.018DOI Listing