A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Performance of the vibrating membrane aerosol generation device: Aeroneb Micropump Nebulizer. | LitMetric

Performance of the vibrating membrane aerosol generation device: Aeroneb Micropump Nebulizer.

J Aerosol Med

University of Minnesota, Department of Pharmaceutics, Minneapolis, Minnesota 55455, USA.

Published: February 2008

The output and particle size distribution of several series of aqueous solutions were measured to define quantitatively the practical limits of the solution properties acceptable for aerosol production by the aeroneb micropump nebulizer. Aerosol output measurements were made gravimetrically and the particle size distributions were obtained by laser diffractometry. Solution properties were obtained from the literature by interpolation of the best-fit curve of the property plotted as a function of composition. For nonionic solutes, addition of sodium chloride dramatically increased the output rate and also decreased the droplet size at low solute concentrations. Increasing viscosity also caused a significant decrease in output. Cesium chloride displayed increased output rate with concentration due to the rising density. Based on calculations with the number of apertures and oscillatory frequency, low output rates appeared to be a consequence of apertures failing to produce a droplet with each oscillation. Overall, ionic strength, density, surface tension, and viscosity affected the output rate in a manner that can be now empirically predicted.

Download full-text PDF

Source
http://dx.doi.org/10.1089/jam.2007.0622DOI Listing

Publication Analysis

Top Keywords

output rate
12
aeroneb micropump
8
micropump nebulizer
8
particle size
8
solution properties
8
increased output
8
output
7
performance vibrating
4
vibrating membrane
4
membrane aerosol
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!