A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

In vivo measurements of cone photoreceptor spacing in myopic eyes from images obtained by an adaptive optics fundus camera. | LitMetric

Purpose: To determine the cone spacing in normal and myopic eyes from the images obtained by an adaptive optics (AO) fundus camera.

Methods: Nineteen eyes of 19 healthy volunteers with a mean +/- SD spherical equivalent refractive error of -3.7 +/- 3.3 diopters (D) (range, -0.3 to -11.1 D) and a mean axial length of 25.4 +/- 1.61 mm (range, 23.4-28.0 mm) were investigated in a prospective cross-sectional study. An AO fundus camera equipped with a liquid crystal phase modulator was used to obtain the images of the photoreceptor mosaic. The spacing between the cones was calculated manually at a retinal locus 2 degrees temporal from the center of the fovea. The magnification of the image was calculated by the axial length measured with an IOL Master.

Results: The axial length was correlated with the refractive error (Pearson, r = -0.869; P < 0.001). The average cone spacing in the moderate- to high-myopia group (-6.5 +/- 2.3 D, n = 9) was 4.71 +/- 0.44 microm, which was significantly greater (P = 0.002) than the 3.90 +/- 0.47 microm in the normal and low-myopia groups (-1.1 +/- 0.9 D, n = 10). The cone spacing was significantly correlated with the axial length (r = 0.77, P < 0.001).

Conclusions: The AO fundus camera is capable of acquiring images of the photoreceptors in normal and myopic eyes. The greater spacing between cones in the myopia group is consistent with histological findings. These results suggest that retinal expansion should be considered in addition to Knapp's law when aniseikonia is evaluated in axial myopia.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10384-007-0477-7DOI Listing

Publication Analysis

Top Keywords

axial length
16
myopic eyes
12
fundus camera
12
cone spacing
12
eyes images
8
images adaptive
8
adaptive optics
8
optics fundus
8
normal myopic
8
refractive error
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!