Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: To determine the cone spacing in normal and myopic eyes from the images obtained by an adaptive optics (AO) fundus camera.
Methods: Nineteen eyes of 19 healthy volunteers with a mean +/- SD spherical equivalent refractive error of -3.7 +/- 3.3 diopters (D) (range, -0.3 to -11.1 D) and a mean axial length of 25.4 +/- 1.61 mm (range, 23.4-28.0 mm) were investigated in a prospective cross-sectional study. An AO fundus camera equipped with a liquid crystal phase modulator was used to obtain the images of the photoreceptor mosaic. The spacing between the cones was calculated manually at a retinal locus 2 degrees temporal from the center of the fovea. The magnification of the image was calculated by the axial length measured with an IOL Master.
Results: The axial length was correlated with the refractive error (Pearson, r = -0.869; P < 0.001). The average cone spacing in the moderate- to high-myopia group (-6.5 +/- 2.3 D, n = 9) was 4.71 +/- 0.44 microm, which was significantly greater (P = 0.002) than the 3.90 +/- 0.47 microm in the normal and low-myopia groups (-1.1 +/- 0.9 D, n = 10). The cone spacing was significantly correlated with the axial length (r = 0.77, P < 0.001).
Conclusions: The AO fundus camera is capable of acquiring images of the photoreceptors in normal and myopic eyes. The greater spacing between cones in the myopia group is consistent with histological findings. These results suggest that retinal expansion should be considered in addition to Knapp's law when aniseikonia is evaluated in axial myopia.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s10384-007-0477-7 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!