Blind deconvolution: multiplicative iterative algorithm.

Opt Lett

Institute of Optics and Electronics, Chinese Academy of Sciences, Chengdu 610209, China.

Published: January 2008

A new algorithm has been developed for performing blind deconvolution on degraded images. The algorithm naturally preserves the nonnegative constraint on the iterative solutions of blind deconvolution and can produce a restored image of high resolution. Furthermore, benefiting from the multiplicative form, the algorithm is free from the instability of numerical computation. Results of applying the algorithm to simulated and real degraded images are reported.

Download full-text PDF

Source
http://dx.doi.org/10.1364/ol.33.000025DOI Listing

Publication Analysis

Top Keywords

blind deconvolution
12
degraded images
8
algorithm
5
deconvolution multiplicative
4
multiplicative iterative
4
iterative algorithm
4
algorithm algorithm
4
algorithm developed
4
developed performing
4
performing blind
4

Similar Publications

Current deep learning-based phase unwrapping techniques for iToF Lidar sensors focus mainly on static indoor scenarios, ignoring motion blur in dynamic outdoor scenarios. Our paper proposes a two-stage semi-supervised method to unwrap ambiguous depth maps affected by motion blur in dynamic outdoor scenes. The method trains on static datasets to learn unwrapped depth map prediction and then adapts to dynamic datasets using continuous learning methods.

View Article and Find Full Text PDF

Optical-resolution photoacoustic microscopy enables cellular-level biological imaging in deep tissues. However, acquiring high-quality spatial images without knowing the point spread function (PSF) at multiple depths or physically improving system performance is challenging. We propose an adaptive multi-layer photoacoustic image fusion (AMPIF) approach based on blind deconvolution and registration.

View Article and Find Full Text PDF

Background: Egg-based inactivated quadrivalent seasonal influenza vaccine (eIIV4), cell culture-based inactivated quadrivalent seasonal influenza vaccine (ccIIV4), and recombinant haemagglutinin (HA)-based quadrivalent seasonal influenza vaccine (RIV4) have been licensed for use in the USA. In this study, we used antigen-specific serum proteomics analysis to assess how the molecular composition and qualities of the serological antibody repertoires differ after seasonal influenza immunisation by each of the three vaccines and how different vaccination platforms affect the HA binding affinity and breadth of the serum antibodies that comprise the polyclonal response.

Methods: In this comparative, prospective, observational cohort study, we included female US health-care personnel (mean age 47·6 years [SD 8]) who received a single dose of RIV4, eIIV4, or ccIIV4 during the 2018-19 influenza season at Baylor Scott & White Health (Temple, TX, USA).

View Article and Find Full Text PDF

Multi-frame blind deconvolution using X-ray microscope images of an in-plane rotating sample.

Sci Rep

November 2024

Department of Materials Physics, Graduate School of Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya, Aichi, 464-8603, Japan.

We propose a multi-frame blind deconvolution method using an in-plane rotating sample optimized for X-ray microscopy, where the application of existing deconvolution methods is technically difficult. Untrained neural networks are employed as the reconstruction algorithm to enable robust reconstruction against stage motion errors caused by the in-plane rotation of samples. From demonstration experiments using full-field X-ray microscopy with advanced Kirkpatrick-Baez mirror optics at SPring-8, a spatial resolution of 34 nm (half period) was successfully achieved by removing the wavefront aberration and improving the apparent numerical aperture.

View Article and Find Full Text PDF

This Letter investigates the influence of source motion on the performance of the ray-based blind deconvolution algorithm (RBD). RBD is used to estimate channel impulse responses and source signals from opportunistic sources such as shipping vessels but was derived under a stationary source assumption. A theoretical correction for Doppler from a simplified moving source model is used to quantify the biases in estimated arrival angles and travel times from RBD.

View Article and Find Full Text PDF