Background: In order to reduce the diagnostic window period between the time of human immunodeficiency virus (HIV) infection and serological diagnosis, new fourth generation screening assays which detect HIV p24 antigen and specific antibody simultaneously have been developed. In this study, we evaluated the performance of a new fourth generation assay.

Methods: We compared a new fourth generation assay, Architect HIV Ag/Ab combo, with another fourth generation assay AxSYM HIV Ag/Ab combo and a third generation assay, AxSYM HIV 1/2 gO for their performance. The assays were evaluated using 3 HIV seroconversion panels, 305 sera of healthy subjects and 100 sera of patients with HBsAg or anti-HCV antibodies. Within-run and total coefficient variations of the three screening assays were analyzed for the evaluation of precision.

Results: Architect HIV Ag/Ab combo shortened the window period by 8.7+/-2.1 days relative to AxSYM HIV 1/2 gO and 2.0+/-2.0 days relative to AxSYM HIV Ag/Ab combo in seroconversion panels. Architect HIV Ag/Ab combo presented the best performance in precision among the three reagents; total CV for positive control was 3.6%, 9.6% and 4.6% for Architect HIV Ag/Ab combo, AxSYM HIV Ag/Ab combo and AxSYM HIV 1/2 gO, respectively. Specificities of three assays were not different in this study.

Conclusions: HIV Ag/Ab combined assays reduced the diagnostic window as compared to the third generation screening assays, enabling an earlier diagnosis of HIV infection. A new fourth generation assay, Architect HIV Ag/Ab combo presents a better performance than AxSYM HIV Ag/Ab combo, showing improved seroconversion sensitivity and precision.

Download full-text PDF

Source
http://dx.doi.org/10.3343/kjlm.2006.26.1.39DOI Listing

Publication Analysis

Top Keywords

hiv ag/ab
40
ag/ab combo
36
axsym hiv
28
fourth generation
24
architect hiv
20
hiv
18
generation assay
16
screening assays
12
hiv 1/2
12
ag/ab
10

Similar Publications

Architect-HIV Ag/Ab combo chemiluminescence assay is globally recognized for its sensitivity but has a notable false-positive rate. In this study, we aim to evaluate the performance of a new cost-effective screening alternative, the chemiluminescence Ag/Ab combo assay (CL-900i-HIV) from Mindray, China. We selected 195 archived samples categorized according to the INNO-LIA™ HIV I/II, the gold standard confirmatory assay.

View Article and Find Full Text PDF

Evaluation of the MAGLUMI HIV Ab/Ag combi test for the detection of HIV infection.

Virol J

November 2024

Center of Clinical Laboratory Medicine, Zhongda Hospital, Southeast University, Nanjing, 210009, People's Republic of China.

Background: Human immunodeficiency virus (HIV) infection screening and diagnosis are critical to control the HIV epidemic. Testing for anti-HIV antibodies (Ab) and antigens (Ag) in blood samples is the first step to screen people who have been potentially exposed to the virus. This study aimed to evaluate the performance of the MAGLUMI HIV Ab/Ag Combi for detection of HIV antibodies and antigens.

View Article and Find Full Text PDF

Background: Despite saving a vast number of lives through blood transfusions, transfusion-transmitted infections (TTIs) still threaten the lives of people needing blood transfusion. Hence, screening blood donors and reviewing the prevalence of TTIs amongst blood donors might show the impact of these infections among our people. The aim of this study was to evaluate the prevalence rates of transfusion-transmitted infections among blood donors in Makkah as foundation for providing harmless blood transfusion in Makkah, Saudi Arabia.

View Article and Find Full Text PDF

In the field of healthcare, quality and efficiency are of paramount importance to ensure the provision of safe and reliable diagnostic services. Blood screening laboratories play a critical role in detecting and preventing the spread of infectious diseases, ensuring the safety of blood transfusions, and supporting medical diagnoses. To enhance the quality of processes in such laboratories, the Six Sigma methodology has gained significant recognition for its ability to systematically identify and minimize variations, thereby improving overall efficiency and reducing errors.

View Article and Find Full Text PDF

Background: Evaluating the clinical performance of Elecsys HIV Duo assay for primary human immunodeficiency virus (HIV) screening and acute HIV infection detection.

Methods: This study was conducted from April 2022 to April 2023 and involved two distinct populations. For the HIV screening population, three HIV Duo results [HIV Duo, HIV antigen (Ag), and HIV antibody (Ab)] in primary screening were obtained (January 2021 to June 2021).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!