A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Study on the ocular pharmacokinetics of ion-activated in situ gelling ophthalmic delivery system for gatifloxacin by microdialysis. | LitMetric

The poor bioavailability and therapeutic response exhibited by conventional ophthalmic solutions due to rapid precorneal elimination of the drug may be overcome by the use of gel system. The present work was conducted to evaluate the relative bioavailability of ion-activated in situ ophthalmic gel of gatifloxacin by microdialysis. The conventional ophthalmic solution of gatifloxacin was used as reference. The AUC of test group is 3.8-fold vs. the reference group (1.4316 +/- 0.1327 microg.mL(-1).h vs. 0.3756 +/- 0.0380 microg.mL(-1).hr) (P < 0.05), and the C(max) of test group vs. the control group is 3.0-fold (0.3363 +/- 0.0634 microg.mL(-1) vs. 0.1112 +/- 0.0151 microg.mL(-1)) (P < 0.05). The T(max) of test group is longer than that of reference group (2.0 +/- 0.67 hr vs. 0.667 +/- 0.17 hr) (P < 0.1), and K(e) of test group is lower than that of reference group. The developed formulation has a higher bioavailability and longer residence time in aqueous humor than conventional ophthalmic solutions. The developed system is a viable alternative to conventional eye drops.

Download full-text PDF

Source
http://dx.doi.org/10.1080/03639040701397241DOI Listing

Publication Analysis

Top Keywords

test group
16
conventional ophthalmic
12
reference group
12
ion-activated situ
8
gatifloxacin microdialysis
8
ophthalmic solutions
8
group
8
+/-
6
ophthalmic
5
study ocular
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!