Purpose: To evaluate the effect of computer-aided detection (CAD) as second reader on radiologists' diagnostic performance in interpreting computed tomographic (CT) colonographic examinations by using a primary two-dimensional (2D) approach, with segmental, unblinded optical colonoscopy as the reference standard.

Materials And Methods: This HIPAA-compliant study was IRB-approved with written informed consent. Four board-certified radiologists analyzed 60 CT examinations with a commercially available review system. Two-dimensional transverse views were used for initial polyp detection, while three-dimensional (3D) endoluminal and 2D multiplanar views were available for problem solving. After initial review without CAD, the reader was shown CAD-identified polyp candidates. The readers were then allowed to add to or modify their original diagnoses. Polyp location, CT Colonography Reporting and Data System categorization, and reader confidence as to the likelihood of a candidate being a polyp were recorded before and after CAD reading. The area under the receiver operating characteristic (ROC) curve (AUC), sensitivity, and specificity were estimated for CT examinations with and without CAD readings by using multireader multicase analysis.

Results: Use of CAD led to nonsignificant average reader AUC increases of 0.03, 0.03, and 0.04 for patients with adenomatous polyps 6 mm or larger, 6-9 mm, and 10 mm or larger, respectively (P > or = .25); likewise, CAD increased average reader sensitivity by 0.15, 0.16, and 0.14 for those respective groups, with a corresponding decrease in specificity of 0.14. These changes achieved significance for the 6 mm or larger group (P < .01), 6-9 mm group (P < .02), and for specificity (P < .01), but not for the 10 mm or larger group (P > .16). The average reading time was 5.1 minutes +/- 3.4 (standard deviation) without CAD. CAD added an average of 3.1 minutes +/- 4.3 (62%) to each reading (supine and prone positions combined); average total reading time, 8.2 minutes +/- 5.8.

Conclusion: Use of CAD led to a significant increase in sensitivity for detecting polyps in the 6 mm or larger and 6-9 mm groups at the expense of a similar significant reduction in specificity.

Download full-text PDF

Source
http://dx.doi.org/10.1148/radiol.2453062161DOI Listing

Publication Analysis

Top Keywords

minutes +/-
12
cad
9
computer-aided detection
8
second reader
8
cad led
8
average reader
8
polyps larger
8
larger 6-9
8
larger group
8
reading time
8

Similar Publications

Several mechanisms were postulated to reduce drilling problems, improve hole cleaning characteristics, and keep the bit in good condition for the second usage. This study was conducted on Majnoon Field in southeastern Iraq to optimize the bit and drilling parameters. The results indicated that the 16" SFD75D bit proved the preferred bit for both vertical and deviated wells due to its directional capabilities.

View Article and Find Full Text PDF

In order to solve the limitations of flipped classroom in personalized teaching and interactive effect improvement, this paper designs a new model of flipped classroom in colleges and universities based on Virtual Reality (VR) by combining the algorithm of Contrastive Language-Image Pre-Training (CLIP). Through cross-modal data fusion, the model deeply combines students' operation behavior with teaching content, and improves teaching effect through intelligent feedback mechanism. The test data shows that the similarity between video and image modes reaches 0.

View Article and Find Full Text PDF

Direct printed aligners (DPAs) offer benefits like the ability to vary layer thickness within a single DPA and to 3D print custom-made removable orthodontic appliances. The biocompatibility of appliances made from Tera Harz TA-28 (Graphy Inc., Seoul, South Korea) depends on strict adherence to a standardized production and post-production protocol, including UV curing.

View Article and Find Full Text PDF

The high performance of two-dimensional (2D) channel membranes is generally achieved by preparing ultrathin or forming short channels with less tortuous transport through self-assembly of small flakes, demonstrating potential for highly efficient water desalination and purification, gas and ion separation, and organic solvent waste treatment. Here, we report the construction of vertical channels in graphene oxide (GO) membrane based on a substrate template with asymmetric pores. The membranes achieved water permeance of 2647 L m h bar while still maintaining an ultrahigh rejection rate of 99.

View Article and Find Full Text PDF

Objective: To determine the effects of rapid (1 minute) and slow (10 minutes) intravenous (IV) injection of sodium penicillin on arterial blood pressure in anesthetized horses.

Study Design: Prospective randomized clinical trial.

Animals: A group of 29 client-owned horses of various breeds, 1-20 years old, with body masses of 360-710 kg.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!