[Analysis of microalbuminuria with immunonephelometry and high performance liquid chromatography. Evaluation of new criteria].

Orv Hetil

Pécsi Tudományegyetem, Altalános Orvostudományi Kar II. Belgyógyászati Klinika és Nefrológiai Centrum Pécs Pacsirta u. 1. 7624.

Published: January 2008

Introduction: Hypertension as well as type 2 diabetes mellitus is a major factor in population mortality. Both diseases damage the endothelium, the early sign of which is microalbuminuria, which can be screened by dipstick and can be diagnosed by using immuno-based and high performance liquid chromatography methods. Using high performance liquid chromatography, the non-immunoreactive albumin can be detected as well.

Aims: The authors aimed at the examination of albuminuria in the case of immunonephelometrically negative patients with high performance liquid chromatography, in diabetic and hypertensive and non-diabetic hypertensive populations. The authors also wanted to compare the present (albumin-creatinine ratio: male: > or =2.5 mg/mmol, female: > or =3.5 mg/mmol) and a new criteria of the Heart Outcomes Prevention Evaluation study (patients without diabetes: immunological method, > or =0.7 mg/mmol; high performance liquid chromatography, > or =3.1 mg/mmol; individuals with diabetes: immunological method, > or =1.4 mg/mmol; high performance liquid chromatography, > or =5.2 mg/mmol) of microalbuminuria.

Methods: Examination of fresh urines of 469 microalbuminuria negative patients by dipstick were performed by immunonephelometry. Patients, who were microalbuminuria negative by immunonephelometry as well, were further analyzed by high performance liquid chromatography using the Accumintrade mark Kit, based on size-exclusion chromatography.

Results: Three times higher albuminuria were found with high performance liquid chromatography than with immunonephelometry. The intraindividual coefficient of variation did not differ in the two methods (37 +/- 31% vs. 40 +/- 31%, p = 0.869; immunonephelometry vs. high performance liquid chromatography; mean +/- standard deviation). Using the present criteria for microalbuminuria, 43% of immunonephelometrically negative patients proved to be microalbuminuric by high performance liquid chromatography. Using the new criteria of the Heart Outcomes Prevention Evaluation study, the rate of microalbuminuria positivity among the immunonephelometrically negative patients decreased to 14.5% by high performance liquid chromatography and the decrease in the number of microalbuminuria positive cases by high performance liquid chromatography could be observed mainly in the diabetic and hypertensive group (49% vs. 7.5%), while slighter decrease could be observed in the non-diabetic hypertensive group (37% vs. 26.5%). Applying the traditional criteria, the strongest predictor was the male gender by the logistic regression analysis. In 28% of microalbuminuria negative patients by immunonephelometry the diagnosis of microalbuminuria can be established using high performance liquid chromatography.

Conclusions: Almost in one-third of microalbuminuria negative patients by immunonephelometry the diagnosis of microalbuminuria can be established by high performance liquid chromatography for which diagnosis three constitutive urine examinations are still needed. New criteria determined by the Heart Outcomes Prevention Evaluation study can be used neither in case of diabetic and hypertensive patients, nor in the case of non-diabetic hypertensive patients. The gender as the most important predictor of microalbuminuria cannot be ignored.

Download full-text PDF

Source
http://dx.doi.org/10.1556/OH.2008.28187DOI Listing

Publication Analysis

Top Keywords

high performance
56
performance liquid
56
liquid chromatography
52
negative patients
24
microalbuminuria negative
16
high
14
performance
14
liquid
14
chromatography
13
immunonephelometrically negative
12

Similar Publications

Development of a 300 kV/3 kHz nanosecond pulse generator using semiconductor opening switches.

Rev Sci Instrum

January 2025

State Key Laboratory of Electrical Insulation and Power Equipment, School of Electrical Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi 710049, China.

In this paper, we present the development of a nanosecond pulse generator utilizing semiconductor opening switches (SOS), designed to deliver high voltage and operate at a high repetitive frequency. The pulse generator comprises three main components: a primary charging unit, a magnetic pulse compression unit, and an SOS magnification unit. To ensure stable operation of the high-power charging unit at high repetitive frequencies, a rectifying resonant charging and energy recovery circuit are implemented, providing a 1 kV charging voltage at a 3 kHz repetition rate.

View Article and Find Full Text PDF

Importance: Obsessive-compulsive and related disorders (OCRDs) encompass various neuropsychiatric conditions that cause significant distress and impair daily functioning. Although standard treatments are often effective, approximately 60% of patients may not respond adequately, underscoring the need for novel therapeutic approaches.

Objective: To evaluate improvement in OCRD symptoms associated with glutamatergic medications as monotherapy or as augmentation to selective serotonin reuptake inhibitors, with a focus on double-blind, placebo-controlled randomized clinical trials (RCTs).

View Article and Find Full Text PDF

Importance: Growing trends in private equity acquisition of acute care hospitals in the US have motivated investigations into quality of care delivered at these health centers. While some studies have explored comparative outcomes for high-acuity medical conditions, care trends and outcomes of complex surgical procedures, such as esophagectomy, at private equity-acquired hospitals is unknown.

Objective: To compare structural characteristics and postoperative outcomes following esophagectomy between private equity-acquired and nonacquired health centers.

View Article and Find Full Text PDF

constructed polymer-layer-modified solid electrolyte enables high-performance all-solid-state batteries.

Chem Commun (Camb)

January 2025

School of Materials Science and Engineering, Zhejiang University, 866 Yuhangtang Rd, Hangzhou 310058, China.

Side reactions between electrolyte and anode hinder the application of solid-state batteries. Here, a polymer-containing composite solid-state electrolyte (LiPSCl@PCSSE) was obtained through polymerization on LiPSCl. The novel electrolyte was indicated to inhibit side reactions, and the pouch cell showed excellent performance, demonstrating its practical application owing to the employment of LiPSCl@PCSSE.

View Article and Find Full Text PDF

Purpose: The aim of the study was to investigate the value of SwiftScan Step-and-Shoot Continuous (SSC) scanning mode in enhancing image quality and to explore appropriate scanning parameters for reducing scan time.

Methods: This study was composed of a phantom study and two clinical tests. The differences in visual image quality scores, coefficient of variance (COV) of the background, image signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and recovery coefficient (RC) of the sphere were compared between SSC mode and traditional Step-and-Shoot (SS) mode in the phantom study.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!