A major problem of optical microscopes is their small depth-of-field (DOF), which hinders automation of micro object manipulation using visual feedback. Wavefront coding, a well-known method for extending DOF, is not suitable for direct application to micro object manipulation systems based on visual feedback owing to its expensive computational cost and due to a trade-off between the DOF and the image resolution properties. To solve such inherent problems, a flexible DOF imaging system using a spatial light modulator in the pupil plane is proposed. Especially, the trade-off relationship is quantitatively analyzed by experiments. Experimental results show that, for low criterion resolution, the DOF increases as the strength of the mask increases, while such a trend was not found for high criterion resolution. With high criterion resolution, the DOF decreases as the mask strength increases when high-resolution images are required. The results obtained can be used effectively to find the optimum mask strength given the desired image resolution.

Download full-text PDF

Source
http://dx.doi.org/10.1364/ao.46.008591DOI Listing

Publication Analysis

Top Keywords

criterion resolution
12
imaging system
8
system spatial
8
spatial light
8
light modulator
8
micro object
8
object manipulation
8
visual feedback
8
image resolution
8
resolution dof
8

Similar Publications

As the clinical applicability of peripheral nerve stimulation (PNS) expands, the need for PNS-specific safety criteria becomes pressing. This study addresses this need, utilizing a novel machine learning and computational bio-electromagnetics modeling platform to establish a safety criterion that captures the effects of fields and currents induced on axons. Our approach is comprised of three steps: experimentation, model creation, and predictive simulation.

View Article and Find Full Text PDF

A recruiting rate () of 0.1-5 s has been proposed as the criterion for super-resolution spontaneously blinking rhodamines. Accurate prediction of the recruiting rate () of rhodamines is very important for developing spontaneously blinking rhodamines.

View Article and Find Full Text PDF

Background: High-dose-rate (HDR) brachytherapy using Iridium-192 as a radiation source is widely employed in cancer treatment to deliver concentrated radiation doses while minimizing normal tissue exposure. In this treatment, the precision with which the sealed radioisotope source is delivered significantly impacts clinical outcomes.

Purpose: This study aims to evaluate the feasibility of a new four-dimensional (4D) in vivo source tracking and treatment verification system for HDR brachytherapy using a patient-specific approach.

View Article and Find Full Text PDF

In recent years, a type of layered oxide, LiNi Mn Co O (NMC) where ++ = 1, has become the preferred cathode material for electric vehicle (EV) batteries. Despite some disorder in the crystal structure due to Li/Ni cation mixing, the composition offers a high specific capacity of up to 200 mAh g at 4.3 V vs Li|Li.

View Article and Find Full Text PDF

An objective soft x-ray flat-field spectrograph employing a laminar-type bilayer coated, varied-line-spacing, spherical grating was designed to improve the detection limit and sensitivity of soft x-ray flat-field spectrographs in a region of 250-550 eV. As a design criterion, spectral flux, SF, [Hatano et al., Appl.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!