For an accurate determination of the absorbed doses in complex radiation fields (e.g. mixed neutron-gamma fields), a better interpretation of the response of ionisation chambers is required. This study investigates a model of the ionisation chambers using a different approach, analysing the collected charge per minute as a response of the detector instead of the dose. The MCNPX Monte Carlo code is used. In this paper, the model is validated using a well-known irradiation field only: a (60)Co source. The detailed MCNPX models of a Mg(Ar) and TE(TE) ionisation chamber is investigated comparing the measured charge per minute obtained free-in-air and in a water phantom with the simulated results. The difference between the calculations and the measurements for the TE(TE) chamber is within +/-2% whereas for the Mg(Ar) chamber is around +7%. The systematic discrepancy in the case of Mg(Ar) chamber is expected to be caused by an overestimation of the sensitive volume.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/rpd/ncm484 | DOI Listing |
Phys Med Biol
December 2024
Division of Radiation Oncology, National Cancer Centre Singapore, 11 Hospital Crescent, Singapore, Singapore, 169610, SINGAPORE.
Reference dosimetry measurement in a pencil beam scanning system can exhibit dose fluctuation due to intra-spill spot positional drift. This results in a noisy reference dosimetry measurement against energy which could introduce errors in monitor unit calibration. The aim of this study is to investigate the impact of smoothing the reference dosimetry measurements on the type A uncertainty.
View Article and Find Full Text PDFMed Phys
December 2024
Division of Ionizing Radiation Metrology, National Institute of Metrology (NIM), Beijing, China.
Background: The clinical use of flattening filter free (FFF) radiotherapy has significantly increased in recent years due to its effective enhancement of dose rates and reduction of scatter dose. A proposal has been made to adjust the incident electron angle of the accelerator to expand the application of FFF beams in areas such as large planning target volumes (PTVs). However, the inherent softening characteristics and non-uniformity of lateral dose distribution in FFF beams inevitably lead to increased dosimetry errors, especially for ionization chambers widely used in clinical practice, which may result in serious accidents during FFF radiotherapy.
View Article and Find Full Text PDFAppl Radiat Isot
December 2024
Radiation Physics Division, National Institute of Standards and Technology, 100 Bureau Dr., Gaithersburg, MD, 20899-8462, USA.
The massic activity of Ac in 0.1 mol/L HCl was measured by multiple primary methods over four consistent measurement campaigns. Results from the triple-to-double coincidence ratio (TDCR) method of liquid scintillation (LS) counting were in accord with other LS-based primary methods.
View Article and Find Full Text PDFBiomed Phys Eng Express
December 2024
Medical Physics Consultant, INTECNUS Foundation, RP82 8400, San Carlos de Bariloche, Río Negro, Argentina.
. To investigate the effect of the position and orientation of the detector and its influence on the determination of output factors (OF) for small fields for a linear accelerator (MR-linac) integrated with 1.5 T magnetic resonance following the TRS-483 formalism.
View Article and Find Full Text PDFRadiat Prot Dosimetry
December 2024
Former staff of Secondary Standard Dosimetry Laboratory, Centro de Protección e Higiene de la Radiaciones, Carretera La Victoria II Km 2½, e/Monumental y Final, Guanabacoa, La Habana, 11100, Cuba.
The present work describes the results for the bilateral comparison between the Secondary Standards Dosimetry Laboratories of the Instituto Nacional de Investigaciones Nucleares (SSDL-ININ), Mexico, and the pilot laboratory, the Centro de Protección e Higiene de las Radiaciones (SSDL-CPHR), Cuba, for the realization of the air kerma (${\boldsymbol{K}}_{\boldsymbol{a}}$) quantity to: (i) diagnostic X-ray (DXR) IEC 61267:2005 beam qualities: RQR 5 RQR 9, RQT 8, and RQT 9 and (ii) radiation protection (RP) ISO 4037:2019 X-ray beam qualities: N60, N100, and W60, as well S-Cs for gamma radiation. The matched and characterized reference fields are realized at SSDL-ININ with a Toshiba E7252FX X-ray tube. In all cases, the ${\boldsymbol{K}}_{\boldsymbol{a}}$ measurements are traceable to PTB, except for S-Cs, traceable to ININ.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!