Hybrid total knee arthroplasty analysis of component failures at an average of 15 years.

J Arthroplasty

Heekin and Deshmukh Orthopaedics, Jacksonville, Florida 32204, USA.

Published: December 2007

Hybrid total knee arthroplasty in which the femoral component is cementless and the tibial component is cemented remains controversial. We report on the long-term results of 65 total knee arthroplasties followed for an average of 15 years. There were 18 revisions (27%); of these, 11 were femoral component revisions. The overall implant survival with revision as the end point was estimated as 64% at 15 years. The femoral component survivorship at 15 years was 72%. Because of the high failure rate, hybrid fixation on the femoral side with this design has been abandoned at our institution; but hybrid fixation with a trabecular metal tibia is currently under investigation.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.arth.2007.04.007DOI Listing

Publication Analysis

Top Keywords

total knee
12
femoral component
12
hybrid total
8
knee arthroplasty
8
average years
8
hybrid fixation
8
component
5
hybrid
4
arthroplasty analysis
4
analysis component
4

Similar Publications

Establishing normative values and understanding how proprioception varies among body parts is crucial. However, the variability across individuals, especially adolescents, makes it difficult to establish norms. This prevents further investigation into classifying patients with abnormal proprioception.

View Article and Find Full Text PDF

Purpose: The goals of this study were (1) to assess whether the preoperative difference between modalities and extent of deformity are associated with a higher difference between planned and achieved surgical correction and (2) if they yield a higher probability of intraoperative adjustments.

Methods: Retrospective single-centre analysis of patients undergoing patient-specific instrumented (PSI) total knee arthroplasty (TKA). Preoperative radiographic parameters were analysed on weightbearing (WB) long-leg radiographs (LLR) and nonweightbearing (NWB) computed tomography (CT).

View Article and Find Full Text PDF

Purpose: The purpose of this study was to generate knowledge about the epidemiology and risk factors for anterior cruciate ligament (ACL) injuries in handball. It was hypothesised that the incidence of ACL injuries is high and comparable to other pivoting sports like football.

Methods: This study is based on the prospective 'ACL registry in German Sports' implemented in the 2016-2017 season.

View Article and Find Full Text PDF

Background: Health-related quality of life (HRQL) is an important endpoint when evaluating the effectiveness of interventions in people living with hip and knee osteoarthritis (OA). The aim of this study was to generate domains for a new OA-specific preference-based index of HRQL in people living with hip or knee OA.

Methods: The proposed HRQL index was based on a formative measurement model.

View Article and Find Full Text PDF

The incidence of venous thromboembolism is low when risk stratification-based thromboprophylaxis is used after fast-track hip and knee arthroplasty.

BMC Musculoskelet Disord

December 2024

Department of Surgery, Hospital Nova of Central Finland, Wellbeing Services County of Central Finland, Jyväskylä, University of Eastern Finland, Kuopio, Finland.

Background: The optimal length of thromboprophylaxis after total hip or knee arthroplasty (THA and TKA) is unknown. Fast-track protocols have improved patient care and led to shorter immobilization and length of stay (LOS) after THA and TKA, thereby diminishing venous thromboembolism (VTE) risk. Here, we investigated risk stratification-based thromboprophylaxis after fast-track THA and TKA.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!