Purpose: A possible complication in regard to osteosynthetic treatment of a lower radius fracture with a locking plate is perforation of the articular surface by screws or a malpositioned ulnar fragment. In order to create good conditions for a homogeneous, reproducible X-ray picture for post-operative imaging control, an appliance for the production of standardised X-ray views has been devised.
Materials And Methods: The X-ray device was constructed at an angle of 20 degrees to the camera. The arm was positioned on the appliance in the side beam path, in shoulder adduction as well as in the dp-beam in 90 degrees abduction of the shoulder.
Results: Through standardisation of the X-ray technique the appliance it is able to supply comparable and reproducible X-ray images. In practice, the representation of both the joint gap and the bolt in the resulting image could be improved.
Conclusions: Better and comparable picture series can be created by standardisation of the imaging technique using this X-ray device.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1055/s-2007-989315 | DOI Listing |
Arch Bone Jt Surg
January 2025
Clinical Orthopaedic Surgery, Shoulder & Elbow Division, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
Objectives: The purpose of this study is to evaluate the outcomes of a polyaxial locking plate utilizing locking-cap fixation for treatment of patients with displaced olecranon fractures.
Methods: A retrospective review was performed for all consecutive patients at two institutions with displaced olecranon fractures treated with a polyaxial locking plate. Patients were required to have at least 1-year follow up.
Indian J Orthop
February 2025
Department of Orthopaedics, PARAS HMRI Hospital, Patna, Bihar 800014 India.
Introduction: Aseptic nonunion is prevalent in orthopedic practice, causing persistent pain and functional impairment. Humeral shaft fractures, accounting for 3-5% of all fractures, have nonunion rates of 2-33% in nonoperative and 5-10% in surgical management. This study, the largest case series on operative management of aseptic humeral shaft nonunion (AHSN), treated with plate osteosynthesis.
View Article and Find Full Text PDFRes Vet Sci
January 2025
United States Military Academy, Department of Chemistry and Life Science, West Point, NY, United States of America.
Objective: The objective of this study was to compare the strength and stiffness of 1.5 mm and 2.0 mm locking plates with various screw fixation configurations applied to the tibia bones of rabbits.
View Article and Find Full Text PDFJ Hand Surg Eur Vol
January 2025
Department of Hand Surgery, Strasbourg University Hospitals, FMTS, 1 avenue Molière, 67200 Strasbourg, France.
Front Surg
January 2025
Department of Orthopedics, Affiliated Zhongshan Hospital of Dalian University, Dalian, China.
Objective: To compare the efficacy of three treatment methods for older adult patients with osteoporotic proximal humerus fractures: proximal humerus locking plate (PHILOS) combined with calcium sulfate injection, PHILOS plate alone, and artificial hemi-shoulder joint replacement.
Methods: The clinical data of 48 older adult patients with osteoporotic proximal humerus fractures admitted to the Shoulder and Elbow Surgery Department of Zhongshan Hospital Affiliated with Dalian University from February 2018-August 2021 were retrospectively analyzed. The patients comprised 18 males and 30 females, with a mean age of (68.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!