Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/S0140-6736(07)61805-4 | DOI Listing |
JAMA Netw Open
January 2025
Alzheimer Center Limburg, Department of Psychiatry and Neuropsychology, School for Mental Health and Neuroscience, Maastricht University, Maastricht, the Netherlands.
Importance: Baseline cerebral microbleeds (CMBs) and APOE ε4 allele copy number are important risk factors for amyloid-related imaging abnormalities in patients with Alzheimer disease (AD) receiving therapies to lower amyloid-β plaque levels.
Objective: To provide prevalence estimates of any, no more than 4, or fewer than 2 CMBs in association with amyloid status, APOE ε4 copy number, and age.
Design, Setting, And Participants: This cross-sectional study used data included in the Amyloid Biomarker Study data pooling initiative (January 1, 2012, to the present [data collection is ongoing]).
Ann Surg Oncol
January 2025
Department of Surgery and Cancer, Imperial College London, London, UK.
Background: Early diagnosis of metastases is crucial but routine staging with contrast-enhanced multidetector computed tomography (ceMDCT) is suboptimal. A total of 20% will have indeterminate or too small to characterize (TSTC) liver lesions on CT, requiring formal characterization by magnetic resonance imaging (MRI). This UK cross-sectional study reports our experience undertaking routine abbreviated liver MRI (MRI).
View Article and Find Full Text PDFJ Magn Reson Imaging
January 2025
Department of Radiology, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, Jiangsu, China.
Background: At high magnetic fields, degraded image quality due to dielectric artifacts and elevated specific absorption rate (SAR) are two technical challenges in fetal MRI.
Purpose: To assess the potential of high dielectric constant (HDC) pad in increasing image quality and decreasing SAR for 3 T fetal MRI.
Study Type: Prospective.
MAGMA
January 2025
Translational Research Imaging Center (TRIC), Clinic of Radiology, University of Münster, Albert-Schweitzer-Campus 1, building A16, 48149, Münster, Germany.
Objective: Invasive multimodal fMRI in rodents is often compromised by susceptibility artifacts from adhesives used to secure cranial implants. We hypothesized that adhesive type, shape, and field strength significantly affect susceptibility artifacts, and systematically evaluated various adhesives.
Materials And Methods: Thirty-one adhesives were applied in constrained/unconstrained geometries and imaged with T2*-weighted EPI at 7.
J Magn Reson Imaging
December 2024
MKS Consulting, Beachwood, Ohio, USA.
The acoustic noise outputs of MR equipment typically require a hearing protection device (HPD) to minimize the likelihood of patient hearing loss. Several different ways to quantify HPD performance have been developed and adopted over many years in different countries across the world (eg, NRR, SNR, SLC80). These HPD evaluations are done in controlled laboratory conditions, following different standardized methodologies, producing different performance ratings for the same HPD, and consequently of a variable relationship with achieved real-world usage performance assessments.