Background: The rapid provision of red cell (RBC) units to patients needing blood urgently is an issue of major importance in transfusion medicine. The development of electronic issue (sometimes termed "electronic crossmatch") has facilitated rapid provision of RBC units by avoidance of the serologic crossmatch in eligible patients. A further development is the issue of blood under electronic control at blood refrigerator remote from the blood bank.

Study Design And Methods: This study evaluated a system for electronic remote blood issue (ERBI) developed as an enhancement of a system for end-to-end electronic control of hospital transfusion. Practice was evaluated before and after its introduction in cardiac surgery.

Results: Before the implementation of ERBI, the median time to deliver urgently required RBC units to the patient was 24 minutes. After its implementation, RBC units were obtained from the nearby blood refrigerator in a median time of 59 seconds (range, 30 sec to 2 min). The study also found that unused requests were reduced significantly from 42 to 20 percent, the number of RBC units issued reduced by 52 percent, the number of issued units that were transfused increased from 40 to 62 percent, and there was a significant reduction in the workload of both blood bank and clinical staff.

Conclusions: This study evaluated a combination of remote blood issue with an end-to-end electronically controlled hospital transfusion process, ERBI. ERBI reduced the time to make blood available for surgical patients and improved the efficiency of hospital transfusion.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1537-2995.2007.01545.xDOI Listing

Publication Analysis

Top Keywords

remote blood
20
rbc units
20
blood issue
16
blood
12
electronic control
12
hospital transfusion
12
electronic remote
8
combination remote
8
system end-to-end
8
end-to-end electronic
8

Similar Publications

Background: Heart failure (HF) is a chronic, progressive condition where the heart cannot pump enough blood to meet the body's needs. In addition to the daily challenges that HF poses, acute exacerbations can lead to costly hospitalizations and increased mortality. High health care costs and the burden of HF have led to the emerging application of new technologies to support people living with HF to stay well while living in the community.

View Article and Find Full Text PDF

Programmable scanning diffuse speckle contrast imaging of cerebral blood flow.

Neurophotonics

January 2025

University of Kentucky, Department of Biomedical Engineering, Lexington, Kentucky, United States.

Significance: Cerebral blood flow (CBF) imaging is crucial for diagnosing cerebrovascular diseases. However, existing large neuroimaging techniques with high cost, low sampling rate, and poor mobility make them unsuitable for continuous and longitudinal CBF monitoring at the bedside.

Aim: We aimed to develop a low-cost, portable, programmable scanning diffuse speckle contrast imaging (PS-DSCI) technology for fast, high-density, and depth-sensitive imaging of CBF in rodents.

View Article and Find Full Text PDF

Polycystic ovarian syndrome (PCOS) is a low-grade and chronic inflammation defined by irregular hormonal status that primarily triggers females in their reproductive age. Multi cysts are a primary manifestation of PCOS; a high level of androgen production characterizes the condition via ovaries. Rheumatoid arthritis (RA) is a chronic, systemic, and symmetrical inflammatory autoimmune disease that affects 1-2% of adults.

View Article and Find Full Text PDF

Anaemia is a prevalent complication in patients with end-stage kidney disease (ESKD) undergoing haemodialysis. This study evaluates the accuracy of the Alio SmartPatchâ„¢, a non-invasive remote monitoring device, in measuring haemoglobin (Hb) and haematocrit (Hct) levels in haemodialysis patients by comparing its results with standard blood-based laboratory methods. The results from 116 patients across multiple sites in the USA and the Kingdom of Jordan show that SmartPatch measurements align closely with standard blood-based laboratory methods, meeting clinically acceptable limits of agreement.

View Article and Find Full Text PDF

Acceptability and Feasibility of Self-Collected Dried Blood Spot Specimens for Viral Load Monitoring among Rural Older People Living with HIV.

AIDS Behav

January 2025

Center for AIDS Intervention Research, Department of Psychiatry and Behavioral Medicine, Medical College of Wisconsin, 2153 N. Dr. Martin Luther King Jr. Dr., Milwaukee, WI, 53212, USA.

Self-collected dried blood spot (DBS) samples may be useful in monitoring viral load (VL) in research studies or clinically given that they eliminate the need for participants to travel to study sites or laboratories. Despite this, little information exists about monitoring VL using DBS self-collected at home, and no information exists on DBS for this use among older rural people living with HIV (PLH), a population that could benefit from self-collection given difficulty accessing care. We report on the feasibility and acceptability of self-collected DBS samples, DBS VL results, concordance between self-reported and DBS VL, and factors associated with DBS detectable VL in a rural Southern U.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!