A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Single-row suture anchor repair of the rotator cuff is biomechanically equivalent to double-row repair in a bovine model. | LitMetric

Purpose: The purpose of this study was to determine biomechanical differences in cyclic elongation and ultimate strength between double-row rotator cuff repair and single-row repair for partial rotator cuff repairs.

Methods: We randomly assigned 18 immature bovine specimens (aged 12 to 16 weeks) to 3 repair groups (6 per group). A 1 x 2-cm defect was created at the infraspinatus tendon insertion site. Two suture anchors were implanted 1 cm apart at the anatomic insertion area for the lateral row. Two suture anchors were implanted 1 cm medial to the lateral row and 1 cm apart from each other for the medial row. Repair groups were constructed as follows: single-row repair with double-loaded suture anchors (group 1), double-row repair with single-loaded medial row and double-loaded lateral row (group 2), and double-row repair with single-loaded medial row and single-loaded lateral row (group 3). Specimens were cyclically loaded from 10 N to 90 N for 500 cycles and then loaded at 0.5 mm/s to failure. Data for cyclic elongation, with loads at 3 mm, 5 mm, and 10 mm, were analyzed via a 1-way analysis of variance (P < .05).

Results: There were no significant differences for peak elongation after cyclic loading between groups. There were no significant differences between repair groups for loads at 3 mm, 5 mm, and 10 mm of elongation. Constructs typically failed by knot slippage (83%), with a single sample having tendon-suture failure (17%).

Conclusions: Double-row repair did not show a biomechanical advantage compared with single-row repair. With this result in mind, the theoretic advantage of a potentially larger footprint must be balanced against the added surgical time, complexity, and cost of double-row repair.

Clinical Relevance: Arthroscopic surgeons should choose the best form of fixation for a given patient, without undue emphasis on single-row repair versus double-row repair. The clinical and biologic impact of footprint restoration was not addressed in this study.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.arthro.2007.07.010DOI Listing

Publication Analysis

Top Keywords

double-row repair
20
single-row repair
16
lateral row
16
repair
14
rotator cuff
12
repair groups
12
suture anchors
12
medial row
12
cyclic elongation
8
anchors implanted
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!