A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Variable echo time imaging: signal characteristics of 1-M gadobutrol contrast agent at 1.5 and 3T. | LitMetric

Variable echo time imaging: signal characteristics of 1-M gadobutrol contrast agent at 1.5 and 3T.

Magn Reson Med

Department of Diagnostic Radiology, Medical Physics, University Hospital Freiburg, Freiburg, Germany.

Published: January 2008

Gadobutrol (Gd-Bt; Gadovist(R), Schering AG) is a 1-M Gadolinium (Gd)-based contrast agent. Its higher Gd concentration allows for reduction of injection volumes in first pass contrast-enhanced MR angiography (CE-MRA) and should increase bolus sharpness and image quality. However, ambivalent results were reported. In order to explore the performance of 1-M contrast agents such as Gd-Bt and its dependence on molecular environment and temperature, signal characteristics were analyzed for a series of increasing Gd-Bt concentrations for different temperature-controlled samples in water and human blood plasma. Relaxation times, relaxivities, and signal-concentration curves were assessed for several Gd-Bt concentrations in water at 20 degrees C and 37 degrees C and in plasma at 37 degrees C for 1.5T and 3T. Gd-Bt concentration influence on signal intensity (SI) could be effectively simulated and compared with experimental measurements as well as simulations with other contrast agents at realistic in vivo concentrations. Particular attention was given to T(2)- and T(*) (2)-induced losses at high concentrations, which annihilate benefits from T(1) shortening. Based on these findings, variable echo time (VTE) approaches with readout bandwidth varying with k-space position were explored in order to enhance the signal to noise performance of gradient echo imaging at high contrast agent concentrations. Results indicate the potential of VTE for imaging with increased SNR at high contrast agent concentrations.

Download full-text PDF

Source
http://dx.doi.org/10.1002/mrm.21345DOI Listing

Publication Analysis

Top Keywords

contrast agent
16
variable echo
8
echo time
8
signal characteristics
8
contrast agents
8
gd-bt concentrations
8
high contrast
8
agent concentrations
8
contrast
6
concentrations
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!