Selection strategies for binaural and monaural cochlear implantation.

Am J Audiol

The University of Iowa, Department of Otolaryngology - Head & Neck Surgery, 200 Hawkins Drive, 21016 PFP, Iowa City, IA 52242, USA.

Published: December 2007

Purpose: We propose theoretical guidelines for cochlear implant selection criteria in adults and children that emphasize the contribution of each ear to the binaural advantage. The guidelines outline options for implanting one ear only, implanting one ear plus use of a contralateral hearing aid, and implanting both ears.

Method: Our method for selecting the best cochlear implant or hearing aid outcome is derived from the amount of usable hearing of the patient. This approach requires the measurement of aided speech perception with each ear separately and then bilaterally. Guidelines are based on the following: (a) overall level of performance with hearing aids relative to what is expected from a cochlear implant, (b) the contributions from each ear, and (c) whether there is a binaural advantage.

Conclusions: Our general recommendation is to provide the patient with the best opportunity for binaural hearing. Since the guidelines put forth in this article are theoretically based, future efforts should be aimed at examining the validity of these guidelines.

Download full-text PDF

Source
http://dx.doi.org/10.1044/1059-0889(2007/011)DOI Listing

Publication Analysis

Top Keywords

cochlear implant
12
ear binaural
8
implanting ear
8
hearing aid
8
guidelines
5
ear
5
hearing
5
selection strategies
4
binaural
4
strategies binaural
4

Similar Publications

Can a Cochlear Implant Be Used as an Electrical Impedance Tomography Device?

Int J Numer Method Biomed Eng

January 2025

Bioengineering, Department of Electrical, Electronic and Computer Engineering, University of Pretoria, Gauteng, South Africa.

The imaging of the live cochlea is a challenging task. Regardless of the quality of images obtained from modern clinical imaging techniques, the internal structures of the cochlea mainly remain obscured. Electrical impedance tomography (EIT) is a safe, low-cost alternative medical imaging technique with applications in various clinical scenarios.

View Article and Find Full Text PDF

Objective: To provide evidence to use an extended frequency pure tone average to screen for cochlear implant evaluation candidates as recommended by the American Cochlear Implant Alliance. Additionally, to determine whether traditional low frequency, high or low frequency, high frequency, or extended frequency pure tone average most accurately predicts cochlear implant candidates based on speech perception scores from aided AzBio sentence testing or aided consonant-nucleus-consonant (CNC) testing.

Method: Adults from a tertiary care center who completed aided sentence testing during cochlear implant evaluation between 2014 and 2024 were assessed.

View Article and Find Full Text PDF

Background: The intraoperative measurements are essential steps in cochlear implant (CI) surgery for confirming correct electrode placement.

Objectives: To examine the intraoperative impedance and electrically evoked action potential (ECAP) measurement results of cochlear implant (CI) users with normal cochlear anatomy (NCA) and to compare them with CI users with inner ear malformations (IEM).

Material And Methods: This retrospective study included intraoperative data of 300 ears from 258 individuals using Medel and Cochlear (Nucleus) CI devices.

View Article and Find Full Text PDF

Background: This investigation quantifies the mean and median hearing thresholds and assesses the prevalence of age-related hearing loss within the senior population of Taipei.

Methods: In a substantive geriatric assessment supported by government initiative, 1696 individuals from a community hospital partook in this cross-sectional study (2016-2018). Detailed audiometric evaluations logged pure-tone thresholds across critical frequencies (0.

View Article and Find Full Text PDF

Objective: Measuring listening effort using pupillometry is challenging in cochlear implant (CI) users. We assess three validated speech tests (Matrix, LIST, and DIN) to identify the optimal speech material for measuring peak-pupil-dilation (PPD) in CI users as a function of signal-to-noise ratio (SNR).

Design: Speech tests were administered in quiet and two noisy conditions, namely at the speech recognition threshold (0 dB re SRT), i.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!