A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Reliability and validity of MR image lung volume measurement in fetuses with congenital diaphragmatic hernia and in vitro lung models. | LitMetric

Purpose: To prospectively assess the reliability of magnetic resonance (MR) image volume measurement in fetuses with congenital diaphragmatic hernia (CDH) and the reliability and validity of measurements in in vitro lung models.

Materials And Methods: This study was approved by the ethics committee, and informed consent was obtained. MR fetal lung volume (FLV) was measured in 40 consecutive fetuses with CDH by using half-Fourier acquired single-shot turbo spin-echo MR imaging and true fast imaging with steady-state precession at 24-36 weeks gestation (mean gestational age, 30.6 weeks +/- 3.5 [standard deviation]). Lung volumes were independently assessed in three orthogonal section planes by two experienced observers. Additionally, 28 in vitro lung models of defined volumes of 1-60 mL were evaluated the same way. To assess measurement validity and reliability, the intraclass correlation coefficient (ICC) and the Bland-Altman plot were used.

Results: The interobserver reliability was high for both the lung models and FLV measurements (ICC, 0.999 and 0.928, respectively). Measurement validity was also good, with a mean difference between the calculated volume and the true volume of 0.4 mL (95% confidence interval: 0.30, 0.48). Measurement reliability and validity did not depend, to any considerable degree, on imaging plane or sequence (ICC range, 0.878-0.999) or on total volume.

Conclusion: The reliability and validity of MR volume measurements are high. The method is independent of the sequence and the imaging plane and can be performed with a very good interobserver agreement, even in small volumes.

Download full-text PDF

Source
http://dx.doi.org/10.1148/radiol.2462062166DOI Listing

Publication Analysis

Top Keywords

reliability validity
16
vitro lung
12
lung models
12
lung volume
8
volume measurement
8
measurement fetuses
8
fetuses congenital
8
congenital diaphragmatic
8
diaphragmatic hernia
8
measurement validity
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!