Stainless steel screws coated with bisphosphonates gave stronger fixation and more surrounding bone. Histomorphometry in rats.

Bone

Section for Orthopaedics, Inst. of Clinical and Experimental Medicine, Faculty of Health Sciences, Linköping University, SE-581 85 Linköping, Sweden.

Published: February 2008

Coating of stainless steel screws with bisphosphonate in a fibrinogen matrix leads to an enhancement of the pullout strength 2 weeks after insertion in rat tibiae. This effect then increases over time until at least 8 weeks. The pullout force reflects the mechanical properties of the bone within the threads, which acts as a screw nut. The aim of the present study was to find descriptive and morphometric histological correlates to the increased pullout strength. Because the bisphosphonates are applied via the implant surface, we also measured bone to implant contact and how far away from the surface any effects could be seen. Stainless steel screws underwent one of three treatments: uncoated control, controls coated with a layer of cross-linked fibrinogen, or screws further modified with bisphosphonates covalently linked and physically adsorbed to the fibrinogen layer. At 1 (n=33) and 8 (n=27) weeks, bone to implant contact and bone area density in the threads were measured, as well as bone area density at 250 and 500 microm from the outer edge of the threads. Additionally, removal torque for each screw treatment was measured at 2 weeks (n=28). At 8 weeks, the part of the bisphosphonate screw that was located in the marrow cavity had become surrounded with bone, whereas there was almost no bone surrounding the controls. The bone area density in the threads along the entire bisphosphonate screw was increased by 40% compared with uncoated controls, and at 250 microm distance it was more than doubled. At 1 week, coated screws had less implant-bone contact, but at 8 weeks there was no difference between uncoated and bisphosphonate-coated screws. The bisphosphonate screws had 50% increased removal torque at 2 weeks compared to uncoated screws. Howship's lacunae and osteoclasts were found near the screws with bisphosphonates at 8 weeks, suggesting that some bone remodeling took place near the implant, in spite of the presence of bisphosphonates.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bone.2007.10.013DOI Listing

Publication Analysis

Top Keywords

stainless steel
12
steel screws
12
bone area
12
area density
12
bone
10
screws
9
screws bisphosphonate
8
pullout strength
8
weeks
8
bone implant
8

Similar Publications

Controlling Listeria monocytogenes and its associated biofilms in the food industry requires various disinfection techniques, including physical, chemical, and biological treatments. Biocides, owing to their ease of use, cost-effectiveness, dissolvability in water, and efficacy against a wide range of microorganisms, are frequently selected options. Nonetheless, concerns have been raised about their efficacy in controlling L.

View Article and Find Full Text PDF

Zeolite coatings are studied as molecular sieves for membrane separation, membrane reactors, and chemical sensor applications. They are also studied as anticorrosive films for metals and alloys, antimicrobial and hydrophobic films for heating, ventilation, and air conditioning, and dielectrics for semiconductor applications. Zeolite coatings are synthesized by hydrothermal, ionothermal, and dry-gel conversion approaches, which require high process temperatures and lengthy times (ranging from hours to days).

View Article and Find Full Text PDF

Introduction: Cephalosporins can trigger hypersensitivity reactions in certain individuals. Consequently, strict regulations restrict the production of non-beta-lactam substances during or after cephalosporin manufacturing. Dry chlorine dioxide gas (dClO), together with ultra-performance liquid chromatography Mass spectrometry/mass spectrometry (UPLC-MS/MS) detection methods, has emerged as a promising method for decontaminating cephalosporin compounds.

View Article and Find Full Text PDF

Early childhood caries (ECC), one of the most common health problems among children aged six years and below, is considered present when one or more surfaces of a tooth are decayed, missing, or filled. Not only does ECC cause pain for a long time, but it also has short- and long-term health consequences in children. In order to treat ECC, holistic management that includes preventive, restorative, and prosthetic intervention is necessary.

View Article and Find Full Text PDF

Unlike many conventional manufacturing techniques, 3D Printing/Additive Manufacturing (3DP/AM) fabrication creates builds with unprecedented degrees of structural and geometrical complexities. However, uncertainties in 3DP/AM processes and material attributes could cause geometric and structural quality issues in resulting builds and products. Evaluating the sensitivity of process parameters and material properties for process optimization, quality assessment, and closed-loop control is crucial in practice.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!