Analysis of exhaled air leads to the development of fast accurate and non-invasive diagnostics. A comprehensive analysis of the entire range of volatile organic compounds (VOCs) in exhaled air samples will enable the identification of VOCs unique for certain patient groups. This study demonstrates proof of principle of our developed method tested on a smoking/non-smoking study population. Thermal desorption and gas chromatography coupled to time-of-flight mass spectrometry were used to analyse exhaled air samples. The VOC profiles obtained from each individual were combined into one final database based on similarity of mass spectra and retention indexes (RI), which offers the possibility for a reliable selection of compounds of interest. As proof of principle we correctly classified all subjects from population of smoking (N=11) and non-smoking (N=11) based on the VOC profiles available in their exhaled air. Support vector machine (SVM) analysis identified 4 VOCs as biomarkers of recent exposure to cigarette smoke: 2,5-dimethyl hexane, dodecane, 2,5-dimethylfuran and 2-methylfuran. This approach contributes to future development of fast, accurate and non-invasive diagnostics of inflammatory diseases including pulmonary diseases.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jchromb.2007.11.008 | DOI Listing |
Healthcare (Basel)
January 2025
Department of Public Health, Gulhane Faculty of Medicine, University of Health Sciences, Ankara 06018, Türkiye.
Tobacco use and exposure to tobacco products remain a major public health challenge, even among athletes. This study aimed to evaluate tobacco use and second-hand smoke exposure in athletes through urinary cotinine levels and exhaled air carbon monoxide (CO) measurements. This cross-sectional study included licensed athletes who visited the sports medicine outpatient clinic of a tertiary hospital.
View Article and Find Full Text PDFSci Rep
January 2025
Dep. Oral Biochemistry, Academic Centre for Dentistry Amsterdam, University of Amsterdam and Vrije Universiteit Amsterdam, Amsterdam, 1081, LA, The Netherlands.
The increasing use of recreational nitrous oxide ([Formula: see text]O) in the Netherlands and its link to traffic accidents highlights the need for reliable detection methods for law enforcement. This study focused on ex vivo detection of [Formula: see text]O in exhaled breath and examining its persistence in the human body. Firstly, a low-cost portable infrared based detector was selected and validated to detect [Formula: see text]O in air.
View Article and Find Full Text PDFEnviron Health (Wash)
January 2025
Department of Occupational and Environmental Health Sciences, School of Public Health, Peking University, Beijing 100191, China.
Indoor environment and health have drawn public attention worldwide. However, the joint health effects and mechanisms of exposure to different types of indoor environmental factors remain unclear. We established an exploratory panel study on indoor environment and health effects among young adults in China (the China IEHE Study) to comprehensively investigate 3M issues, including multiple indoor environmental factors, multiple health effects, and multiple omics methods for mechanism exploration.
View Article and Find Full Text PDFPhotochem Photobiol
January 2025
Department of Biosciences and Bioengineering, Indian Institute of Technology Bombay, Mumbai, Maharashtra, India.
Virus-laden aerosols play a substantial role in the spread of numerous infectious diseases, particularly in enclosed indoor settings. Ultraviolet-C (UVC) disinfection is known to be a highly efficient method for disinfecting pathogenic airborne viruses. Recent recommendations suggest using far-UVC radiation (222 nm) emitted by KrCl* (krypton-chloride) excimer lamps to disinfect high-risk public spaces due to lower exposure risks than low-pressure (LP) mercury lamps (254 nm).
View Article and Find Full Text PDFRespir Physiol Neurobiol
January 2025
School of Mechanical and Mechatronic Engineering, Faculty of Engineering and Information Technology, University of Technology Sydney, Sydney, NSW 2007, Australia. Electronic address:
Central and Obstructive Sleep Apnea (CSA and OSA), Chronic Obstructive Pulmonary Disease (COPD), and Obesity Hypoventilation Syndrome (OHS) disrupt breathing patterns, posing significant health risks and reducing the quality of life. Bilevel Positive Airway Pressure (BiPAP) therapy offers adjustable inhalation and exhalation pressures, potentially enhancing treatment adaptability for the above diseases. This is the first-ever study that employs Computational Fluid Dynamics (CFD) to examine the biomechanical impacts of BiPAP under four settings: Inspiratory Positive Airway Pressure (IPAP)/Expiratory Positive Airway Pressure (EPAP) of 12/8, 16/6, and 18/8 cmHO, compared to a without-BiPAP scenario of zero-gauge pressure.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!