A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A catheter tracking method using reverse polarization for MR-guided interventions. | LitMetric

A catheter tracking method using reverse polarization for MR-guided interventions.

Magn Reson Med

Electrical and Electronics Engineering, Bilkent University, Ankara, Turkey.

Published: December 2007

To conduct interventional procedures in MRI, reliable visualization of interventional devices such as catheters is necessary. For this purpose, the use of inductively-coupled radio frequency (ICRF) coils has been proposed. Without a wired connection, the signal around the ICRF coil is amplified, enabling catheters to be visualized. The wireless connection allows easy handling of catheters, in some pulse sequences, however, it might be difficult to differentiate the catheters from anatomical background information. In this work, a novel ICRF coil visualization method, which allows separation of the catheter and the anatomical information by using the reverse and forward polarization modes of a coil, is proposed. This method allows images of the anatomy and the catheter to be combined into a color-coded image. First, an ICRF coil with decoupling diodes was constructed; we call this a receive-coupled RF (RCRF) coil. The RF safety profile of the RCRF coil is shown to be better than the ICRF coil. Second, to demonstrate the feasibility of this method, a receive-only birdcage coil without a hybrid coupler was constructed and then connected to a scanner as a two-channel phased-array coil. MR signals acquired from two channels were added after phase adjustments to create the reverse and forward polarization mode images. The reverse polarization mode image contained signal only from the RCRF coil, but the forward polarization mode displayed both anatomical information and the RCRF coil. The performance of this novel tracking method was tested in phantom and animal experiments. Color-coded images demonstrate the feasibility of the method to track catheters using RCRF coils.

Download full-text PDF

Source
http://dx.doi.org/10.1002/mrm.21419DOI Listing

Publication Analysis

Top Keywords

icrf coil
16
rcrf coil
16
forward polarization
12
polarization mode
12
coil
11
tracking method
8
reverse polarization
8
method allows
8
reverse forward
8
demonstrate feasibility
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!