Effects of in utero meso-2,3-dimercaptosuccinic acid with calcium and ascorbic acid on lead-induced fetal development.

Arch Toxicol

Department of Nutrition and Food Hygiene, School of Public Health, China Medical University, No. 92 Beier Road, Heping District, Shenyang, Liaoning Postal code: 110001, People's Republic of China.

Published: July 2008

To examine the effects of meso-2,3-dimercaptosuccinic acid (DMSA) on developmental toxicity resulting from exposure to lead in utero, female albino mice were exposed to lead by drinking water contaminated with lead acetate for 4 weeks. After the cessation of lead exposure, female mice were supplemented by gavage with saline solution, DMSA, or DMSA and calcium as well as ascorbic acid from the fourth day of gestation until parturition, respectively. Lead levels (blood, liver, and bone) were measured at birth. Pups were then tested about neural development including surface righting reflex, cliff avoidance and air righting reflex. The markers of physical maturation, such as body weight, pinna unfolding, incisor eruption, and eye opening were also recorded. DMSA treatment decreased blood lead levels of pregnant mice, however, increased lead levels in both liver and bone of fetus, and delayed the early physical and neural development of offspring. Calcium and ascorbic acid reduced the transfer of lead to fetus. In conclusion, DMSA treatment during pregnancy enhances lead-induced fetal developmental toxicity.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00204-007-0267-5DOI Listing

Publication Analysis

Top Keywords

ascorbic acid
12
lead levels
12
meso-23-dimercaptosuccinic acid
8
calcium ascorbic
8
lead-induced fetal
8
developmental toxicity
8
lead
8
liver bone
8
neural development
8
righting reflex
8

Similar Publications

This study reports on the development of a highly sensitive non-enzymatic electrochemical sensor based on a two-dimensional TiCT/MWCNT-OH nanocomposite for the detection of paraoxon-based pesticide. The synergistic effect between the TiCT nanosheet and the functionalized multi-walled carbon nanotubes enhanced the sensor's conductivity and catalytic activity. The nanocomposite demonstrates superior electrochemical and electroanalytical performance compared to the pristine TiCT and MWCNT-OH in detecting paraoxon-ethyl in fruit samples (green and red grapes), with a linear response range from 0.

View Article and Find Full Text PDF

Azo dye was used to prepare a new series of complexes with chlorides of rhodium (Rh), ruthenium (Ru), and corona (Au). The prepared materials were subjected to infrared, ultraviolet-visible, and mass spectrometry, as well as thermogravimetric analysis, differential calorimetry, and elemental analysis. Conductivity, magnetic susceptibility, metal content, and chlorine content of the complexes were also measured.

View Article and Find Full Text PDF

Introduction: Datura stramonium (DS) possesses strong medicinal and therapeutic potential but has been rarely evaluated in this context.

Methods: The present study was intended to evaluate the antioxidant, hepatoprotective, and nephroprotective potential of the crude methanolic leaf extract and ethyl acetate, chloroform, n-hexane, and aqueous fractions of DS in paracetamol-intoxicated rabbits. Paracetamol (2 g/Kg BW) was applied to induce liver and kidney injury in rabbits while the methanolic extract and fractions of DS were applied in the dose range of 150 mg/Kg to 300 mg/Kg body weight for 21 days.

View Article and Find Full Text PDF

The total content of heavy metals (Cd, Co, Cr, Cu, Fe, Mn, Ni, Pb and Zn) in chamomile sample, metals content in water chamomile infusions and water infusions with additions of ascorbic acid and lemon juice at different temperatures (70, 80, and 100 °C) and steeping times (3, 5, and 7 min), were determined. The content of heavy metals was determined by flame atomic absorption spectrometry (FAAS). Mean total concentrations of Cd, Co, Cr, Cu, Fe, Mn, Ni, Pb and Zn were 0.

View Article and Find Full Text PDF

BiS/BiO(OH) nanorods with internal electric field throughout the entire bulk phase as photoelectrochemical sensing platforms for CYFRA21-1 immunoassay.

Anal Chim Acta

February 2025

Key Laboratory of Chemical Sensing & Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, 250022, Jinan, PR China; Department of Chemistry, Sungkyunkwan University, 16419, Suwon, Republic of Korea. Electronic address:

Photoelectrochemical (PEC) immunosensors are highly promising tools for monitoring biochemical molecules. Constructing high-performance heterojunctions is a general method to improve the sensitivity of PEC immunosensors. The internal electric field (IEF) formed at the heterojunction interface plays a crucial role in coordinating the separation of photogenerated carriers.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!