A highly sensitive and enantioselective assay has been developed and validated for the estimation of torcetrapib (TTB) enantiomers [(+)-TTB and (-)-TTB] in hamster plasma with chiral liquid chromatography coupled to tandem mass spectrometry with an atmospheric pressure chemical ionization interface in the negative-ion mode. The assay procedure involves liquid-liquid extraction of TTB enantiomers and IS (DRL-16126) from 100 microL hamster plasma with acetonitrile. TTB enantiomers were separated using n-hexane:propanol (80:20, v/v) at a flow rate of 0.7 mL/min on a Chiralpak AD column. The MS/MS ion transitions monitored were 599.2-->340.2 for TTB and 623.2-->298.1 for IS. Absolute recovery was found to be between 64 and 68% for TTB enantiomers and >100% for IS. The standard curves for TTB enantiomers were linear (r(2)>0.995) in the concentration range 5-2500 ng/mL for each enantiomer with an LLOQ of 5 ng/mL for each enantiomer. The inter- and intra-day precisions were in the range of 10.5-12.4 and 9.15-11.5% and 3.75-12.9 and 5.16-12.5% for (+)-TTB and (-)-TTB, respectively. Accuracy in the measurement of quality control (QC) samples was in the range 91.3-105 and 88.6-111% for (+)-TTB and (-)-TTB, respectively. This novel method has been applied to the study of stereoselective oral pharmacokinetics of (-)-TTB.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jchromb.2007.10.043DOI Listing

Publication Analysis

Top Keywords

ttb enantiomers
20
hamster plasma
12
liquid chromatography
8
atmospheric pressure
8
pressure chemical
8
chemical ionization
8
tandem mass
8
mass spectrometry
8
ng/ml enantiomer
8
+-ttb --ttb
8

Similar Publications

A highly sensitive and enantioselective assay has been developed and validated for the estimation of torcetrapib (TTB) enantiomers [(+)-TTB and (-)-TTB] in hamster plasma with chiral liquid chromatography coupled to tandem mass spectrometry with an atmospheric pressure chemical ionization interface in the negative-ion mode. The assay procedure involves liquid-liquid extraction of TTB enantiomers and IS (DRL-16126) from 100 microL hamster plasma with acetonitrile. TTB enantiomers were separated using n-hexane:propanol (80:20, v/v) at a flow rate of 0.

View Article and Find Full Text PDF

Development and validation of an enantioselective HPLC-UV method using Chiralpak AD-H to quantify (+)- and (-)-torcetrapib enantiomers in hamster plasma--application to a pharmacokinetic study.

J Chromatogr B Analyt Technol Biomed Life Sci

October 2007

Drug Metabolism and Pharmacokinetics, Discovery Research, Dr. Reddy's Laboratories Ltd., Miyapur, Hyderabad-500 049, India.

A chiral selective, accurate and reproducible high-performance liquid chromatographic (HPLC) method was developed and validated for direct separation of individual enantiomers of torcetrapib (TTB) [(+)-TTB and (-)-TTB]. TTB enantiomers and IS were extracted from a small aliquot of plasma (100 microL) by simple liquid-liquid extraction using acetonitrile as extraction solvent. The enantiomers were resolved on Chiralpak AD-H (250 mm x 4.