Study of the sensitivity of the first four flexural modes of an AFM cantilever with a sidewall probe.

Ultramicroscopy

Department of Mechanical Engineering, Kun Shan University, Tainan 710-03, Taiwan, ROC.

Published: June 2008

The resonant frequency and sensitivity of flexural vibration for an atomic force microscope (AFM) cantilever with a sidewall probe have been analyzed. A closed-form expression for the sensitivity of vibration modes has been obtained using the relationship between the resonant frequency and contact stiffness of cantilever and sample. The results show that a sidewall scanning AFM is more sensitive when the contact stiffness is lower and that the first mode is the most sensitive. However, the high-order modes become more sensitive than the low-order modes as the contact stiffness increases. The resonance frequency of an AFM cantilever is low when contact stiffness is small. However, the frequency rapidly increases as contact stiffness increases. In addition, it can be found that the effects of the vertical extension on the sensitivity and the resonant frequency of an AFM cantilever are significant. Decreasing the length of vertical extension can increase the resonance frequency and sensitivity of mode 1 when the contact stiffness is small. However, the situation is reverse when the contact stiffness becomes large.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ultramic.2007.10.003DOI Listing

Publication Analysis

Top Keywords

contact stiffness
28
afm cantilever
16
resonant frequency
12
sensitivity flexural
8
cantilever sidewall
8
sidewall probe
8
frequency sensitivity
8
stiffness increases
8
resonance frequency
8
frequency afm
8

Similar Publications

Neuromuscular Strategies in Dominant and Non-Dominant Legs in Dancers During Dynamic Balance Tasks.

J Dance Med Sci

January 2025

Frontier Research Institute of Convergence Sports Science, College of Educational Sciences, Yonsei University, Seoul, Korea.

Ballet-based dance training emphasizes the equal development of both legs. However, dancers often perceive differences between their legs during balance or landing. There still needs to be more consensus on the functional difference between dominant (D) and non-dominant legs (ND).

View Article and Find Full Text PDF

Temporal parameters are crucial for understanding running performance, especially in elite sports environments. Traditional measurement methods are often labor-intensive and not suitable for field conditions. This study seeks to provide greater clarity in parameter estimation using a single device by comparing it to the gold standard.

View Article and Find Full Text PDF

Nondestructive Monitoring of Textile-Reinforced Cementitious Composites Subjected to Freeze-Thaw Cycles.

Materials (Basel)

December 2024

Department of Mechanics of Materials and Constructions, Faculty of Engineering, Vrije Universiteit Brussel, B-1050 Brussels, Belgium.

Cementitious materials are susceptible to damage not only from mechanical loading, but also from environmental (physical, chemical, and biological) factors. For Textile-Reinforced Cementitious (TRC) composites, durability poses a significant challenge, and a reliable method to assess long-term performance is still lacking. Among various durability attacks, freeze-thaw can induce internal cracking within the cementitious matrix, and weaken the textile-matrix bond.

View Article and Find Full Text PDF

Timber-concrete composites are established structural elements to combine the advantageous properties of both materials by connecting them. In this work, an innovative flexible adhesive connection in different configurations is investigated. Load-bearing capacity, stiffness, and the failure modes were first experimentally investigated by performing push-out tests.

View Article and Find Full Text PDF

Biomaterial scaffold engineering presents great potential in promoting axonal regrowth after spinal cord injury (SCI), yet persistent challenges remain, including the surrounding host foreign body reaction and improper host-implant integration. Recent advances in mechanobiology spark interest in optimizing the mechanical properties of biomaterial scaffolds to alleviate the foreign body reaction and facilitate seamless integration. The impact of scaffold stiffness on injured spinal cords has not been thoroughly investigated.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!