A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A 4-year prospective clinical and radiological study of maxillary dental implants supporting single-tooth crowns using early and delayed loading protocols. | LitMetric

A 4-year prospective clinical and radiological study of maxillary dental implants supporting single-tooth crowns using early and delayed loading protocols.

Clin Implant Dent Relat Res

Department of Restorative and Prosthetic Dentistry, College of Dentistry, The Ohio State University, Columbus, Ohio 43218-2357, USA.

Published: December 2007

Background: Recent studies have showed that immediate/early loading of dental implants is a clinically feasible concept with results similar to those for standard two-stage procedures, especially in the mandible. However, there are only a few studies regarding the immediate/early loading of maxillary implants supporting single-tooth crowns.

Purpose: The aim of this study was to compare the clinical and radiological outcomes of early- and delayed-loaded dental implants supporting single-tooth crowns in the maxilla.

Materials And Methods: Twenty-nine patients were consecutively treated between 2000 and 2002 with 59 Brånemark System MK III TiUnite implants (Nobel Biocare AB, Göteborg, Sweden) in the maxilla. Two groups were formed according to the loading protocols. In the test group, definitive implant-supported single crowns were delivered to 19 patients 6 weeks after the implant placement. In the control group, definitive implant-supported single crowns were delivered to 10 patients 6 months after the implant placement. Clinical and radiographic parameters were recorded at baseline, 1 to 4 years. Implant stability measurements have only been performed at 4-year follow-up recall.

Results: Overall, three implants were lost during the study period. Two implants were lost in the test group including 36 implants, which indicated a survival rate of 94.4%. One of the lost implants was replaced and then osseointegrated successfully. One implant was lost in the control group during the healing period, which indicated a survival rate of 95.7%. The average marginal bone loss was 1.11 mm for 56 implants after 4 years. There were no significant differences in marginal bone levels, insertion torque, and resonance frequency values between the two groups.

Conclusion: The results of this study indicate that 6 weeks of early loading period for TiUnite-surface titanium implants in the maxilla is reliable and predictable for this patient population and may offer an alternative to the standard loading protocol.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1708-8208.2007.00045.xDOI Listing

Publication Analysis

Top Keywords

dental implants
12
implants supporting
12
supporting single-tooth
12
implants
11
clinical radiological
8
single-tooth crowns
8
loading protocols
8
studies immediate/early
8
immediate/early loading
8
test group
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!