Background: Resting electrocardiogram (ECG) shows limited sensitivity and specificity for the detection of coronary artery disease (CAD). Several methods exist to enhance sensitivity and specificity of resting ECG for diagnosis of CAD, but such methods are not better than a specialist's judgement. We compared a new computer-enhanced, resting ECG analysis device, 3DMP, to coronary angiography to evaluate the device's accuracy in detecting hemodynamically relevant CAD.
Methods: A convenience sample of 423 patients without prior coronary revascularization was evaluated with 3DMP before coronary angiography. 3DMP's sensitivity and specificity in detecting hemodynamically relevant coronary stenosis as diagnosed with coronary angiography were calculated as well as odds ratios for the 3DMP severity score and coronary artery disease risk factors.
Results: 3DMP identified 179 of 201 patients with hemodynamically relevant stenosis (sensitivity 89.1%, specificity 81.1%). The positive and negative predictive values for identification of coronary stenosis as diagnosed in coronary angiograms were 79% and 90% respectively. CAD risk factors in a logistic regression model had markedly lower predictive power for the presence of coronary stenosis in patients than did 3DMP severity score (odds ratio 3.35 [2.24-5.01] vs. 34.87 [20.00-60.79]). Logistic regression combining severity score with risk factors did not add significantly to the prediction quality (odds ratio 36.73 [20.92-64.51]).
Conclusions: 3DMP's computer-based, mathematically derived analysis of resting two-lead ECG data provides detection of hemodynamically relevant CAD with high sensitivity and specificity that appears to be at least as good as those reported for other resting and/or stress ECG methods currently used in clinical practice.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2034757 | PMC |
http://dx.doi.org/10.7150/ijms.4.249 | DOI Listing |
J Med Internet Res
January 2025
Hospital Administration, Ramaiah Memorial Hospital, Bengaluru, Karnataka, India.
Background: Monitoring vital signs in hospitalized patients is crucial for evaluating their clinical condition. While early warning scores like the modified early warning score (MEWS) are typically calculated 3 to 4 times daily through spot checks, they might not promptly identify early deterioration. Leveraging technologies that provide continuous monitoring of vital signs, combined with an early warning system, has the potential to identify clinical deterioration sooner.
View Article and Find Full Text PDFAJR Am J Roentgenol
January 2025
Department of Radiology, Division of Breast Imaging and Intervention, Mayo Clinic, Phoenix, AZ.
Contrast-enhanced mammography (CEM) is growing in clinical use due to its increased sensitivity and specificity compared to full-field digital mammography (FFDM) and/or digital breast tomosynthesis (DBT), particularly in patients with dense breasts. To perform an intraindividual comparison of MGD between FFDM, DBT, a combination protocol using both FFDM and DBT (combined FFDM-DBT), and CEM, in patients undergoing breast cancer screening. This retrospective study included 389 women (median age, 57.
View Article and Find Full Text PDFJ Bone Joint Surg Am
November 2024
Department of Orthopedic Surgery, Columbia University Irving Medical Center, New York, NY.
Background: An accurate knowledge of a patient's risk of cord-level intraoperative neuromonitoring (IONM) data loss is important for an informed decision-making process prior to deformity correction, but no prediction tool currently exists.
Methods: A total of 1,106 patients with spinal deformity and 205 perioperative variables were included. A stepwise machine-learning (ML) approach using random forest (RF) analysis and multivariable logistic regression was performed.
Arq Bras Cir Dig
January 2025
Department of Gastroenterology, Hospital das Clinicas, Faculty of Medicine, Universidade de São Paulo - São Paulo (SP), Brazil.
Background: Blood loss during liver transplantation (LT) remains a major concern associated with increased morbidity and reduced patient and graft survival. The high complexity of the procedure associated with the multifaceted origin of the bleeding urges early identification of high-risk patients and proper monitoring of hemostasis disorders in order to improve results. The accuracy of international normalized ratio (INR) and activated partial thromboplastin time (aPTT) to evaluate coagulation status in cirrhotic patients has been doubted.
View Article and Find Full Text PDFJ Chromatogr Sci
January 2025
Division of Chemical and Material Metrology, Korea Research Institute of Standards and Science, 267, Gajeong-ro, Yuseong-gu, Daejeon, 34113Republic of Korea.
We developed a reversed-phased high-performance liquid chromatographic method combining ultraviolet detection and integrated pulsed amperometric detection for the simultaneous quantification of dopamine, 5-hydroxyindolacetic acid, homovanillic acid, serotonin, 3,4-dihydroxyphenylacetic acid, norepinephrine and epinephrine. All target components were completely separated in a C18 column with isocratic elution of 5% acetonitrile solution containing 8 mM HClO4 and 0.20 mM 1-octanesulfonic acid as an ion pairing reagent.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!