The laryngeal mask airway at altitude.

J Emerg Med

Department of Respiratory Care, Mayo Clinic, Rochester, Minnesota 55905, USA.

Published: February 2008

The Laryngeal Mask Airway (LMA) is an accepted adjunct for airway management in emergency patients. There are a number of case reports describing its use in transport medicine for infant to adult patients, including during flight. Although studies of the effect altitude has on air-filled tracheal tubes exists, we were unable to find documentation of the effect of altitude on laryngeal mask airways. Our objective was to assess the effect of altitude on the LMA in both fixed wing and rotary wing models. We performed an in vitro study of the effect of altitude on the LMA cuff. Infant and adult airway trainer mannequins with properly sized and inserted LMA-Classic laryngeal mask airways were monitored for cuff pressure changes while flown at altitudes commonly encountered during air medical transport. Both models demonstrated that LMA cuff pressures may exceed manufacturer recommended levels for safe use even at the relatively low altitudes experienced during rotor wing flight. Properly inserted and inflated laryngeal mask airways at ground level may result in overinflated LMA cuffs when flown to altitudes commonly used for rotor and fixed wing medical transport unless monitored and corrected.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jemermed.2007.04.026DOI Listing

Publication Analysis

Top Keywords

laryngeal mask
20
mask airways
12
mask airway
8
altitude laryngeal
8
infant adult
8
altitude lma
8
fixed wing
8
lma cuff
8
flown altitudes
8
altitudes commonly
8

Similar Publications

Background: The use of laryngeal masks (LM) has increased widely today, both in anesthesia and in emergency cases. LM are available as reusable and disposable. Although reuse of disposable LM is not recommended, they are reused again after decontamination with different methods in anesthesia units in some countries.

View Article and Find Full Text PDF

Objective: The supraglottic airway device is a viable alternative to tracheal intubation for elective surgery. To conduct a comparative analysis of the advantages and disadvantages associated with use of the Baska mask and I-gel across various dimensions.

Design: A comprehensive search was conducted across PubMed, Embase, Cochrane Library, Web of Science, and other relevant databases to identify randomised controlled trials (RCTs) involving patients who used the Baska mask and I-gel.

View Article and Find Full Text PDF

Background: Several health care networks have fully adopted second-generation supraglottic airway (SGA) i-gel. Real-world evidence of enhanced patient safety after such practice change is lacking. We hypothesized that the implementation of i-gel compared to the previous LMA®-Unique™ would be associated with a lower risk of airway-related safety events.

View Article and Find Full Text PDF

Objective: To evaluate the clinical efficacy and safety of ultrasound-guided rectus sheath block (RSB) in laparoscopic umbilical hernia repair with intraperitoneal onlay mesh (IPOM).

Methods: A total of 139 patients scheduled for laparoscopic umbilical hernia repair with IPOM were selected and randomly assigned to either the group receiving general anesthesia combined with bilateral rectus sheath block (Group GR, 71 patients) or the group receiving general anesthesia alone (Group G, 68 patients). We monitored the patients' heart rate (HR) and mean arterial pressure (MAP) at four time points: before anesthesia induction (T1), at the start of surgery (T2), during mesh fixation (T3), and upon removal of the laryngeal mask (T4).

View Article and Find Full Text PDF

: Despite the known impact of propofol and remifentanil on hemodynamics and patient outcomes, there is a lack of comprehensive quantitative analysis, particularly in surgical settings, considering the influence of noxious stimuli. The aim of this study was to develop a quantitative semi-mechanistic population model that characterized the time course changes in mean arterial pressure (MAP) and heart rate (HR) due to the effects of propofol, remifentanil, and different types of noxious stimulation related to the clinical routine. : Data from a prospective study were used; the study analyzed the effects of propofol and remifentanil general anesthesia on female patients in physical status of I-II according to the American Society of Anesthesiologists (ASA I-II) undergoing gynecology surgery.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!