Background: Heart failure is associated with reversal to a fetal gene expression pattern of contractile and metabolic genes. Substantial recovery of ventricular function with assist devices is rare. Our goal was to evaluate the effects of assist devices on fetal gene expression and hypoxia inducible factor-1 alpha (HIF-1 alpha), a transcriptional factor in hypoxic signaling.
Methods: Human heart tissue was obtained from the left ventricular apex at the time of assist device implantation and again from the left ventricular free wall during cardiac transplantation. Non-failing tissue was obtained from unused hearts from human donors. Gene expression was measured with the Affymetrix 133 plus 2 Array. HIF-1 alpha was measured by Western blotting with commercially available antibodies.
Results: Heart failure was associated with a decrease in alpha-myosin heavy chain and sarcoplasmic reticulum-Ca(2+) adenosine triphosphatase messenger RNA expression along with an increase in skeletal tropomyosin. This pattern persisted after assist device therapy. Heart failure was also associated with abnormalities in regulatory metabolic genes including glucose transporter 1 (GLUT1). These patterns also persisted after assist device therapy despite a reduction in atrial natriuretic peptide expression and normalization of HIF-1 alpha.
Conclusions: Failure of assist devices to produce sustained recovery of myocardial contractile function may be due in part to persistent fetal transcriptional patterns of contractile and metabolic genes.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2768343 | PMC |
http://dx.doi.org/10.1016/j.healun.2007.08.003 | DOI Listing |
Anal Chem
January 2025
State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Key Laboratory for Bio-Nanotechnology and Molecular Engineering of Hunan Province, Hunan University, Changsha 410082, China.
To facilitate on-site detection by nonspecialists, there is a demand for the development of portable "sample-to-answer" devices capable of executing all procedures in an automated or easy-to-operate manner. Here, we developed an automated detection device that integrated a magnetofluidic manipulation system and a signal acquisition system. Both systems were controllable via a smartphone.
View Article and Find Full Text PDFBMC Health Serv Res
January 2025
Institute Patient-Centered Digital Health, Bern University of Applied Sciences, Quellgasse 21, Biel, 2502, Switzerland.
Background: Hospital at home (HaH) care models have gained significant attention due to their potential to reduce healthcare costs, improve patient satisfaction, and lower readmission rates. However, the lack of a standardized classification system has hindered systematic evaluation and comparison of these models. Taxonomies serve as classification systems that simplify complexity and enhance understanding within a specific domain.
View Article and Find Full Text PDFAdv Mater
January 2025
Institute for Advanced Materials & Guangdong Provincial Key Laboratory of Optical Information Materials and Technology, South China Academy of Advanced Optoelectronics, South China Normal University, Guangzhou, 510006, China.
Laboratory-scale spin-coating techniques are widely employed for fabricating small-size, high-efficiency perovskite solar cells. However, achieving large-area, high-uniformity perovskite films and thus high-efficiency solar cell devices remain challenging due to the complex fluid dynamics and drying behaviors of perovskite precursor solutions during large-area fabrication processes. In this work, a high-quality, pinhole-free, large-area FAPbI perovskite film is successfully obtained via scalable blade-coating technology, assisted by a novel bidirectional Marangoni convection strategy.
View Article and Find Full Text PDFSci Rep
January 2025
The BioRobotics Institute, Scuola Superiore Sant'Anna, Pontedera, Pisa, Italy.
Millions of individuals surviving a stroke have lifelong gait impairments that reduce their personal independence and quality of life. Reduced walking speed is one of the major problems limiting community mobility and reintegration. Previous studies have shown positive effect of robot-assisted gait training utilizing hip exoskeletons for individuals with gait impairments due to a stroke, leading to increased walking speed in post-treatment compared to pre-treatment assessments.
View Article and Find Full Text PDFWorld J Pediatr Congenit Heart Surg
January 2025
The Heart Institute, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA.
Background: With an increasing number of Fontan patients surviving into adulthood, the burden of end-stage heart failure is increasing. Prior studies have reported suboptimal heart transplantation (HTx) outcomes. Therefore, the authors describe their institutional experience of HTx in patients with Fontan circulation failure, including heart-liver transplantation (HLTx) and pretransplant systemic ventricular assist device (SVAD) therapies.