Background: Accurate estimation of left ventricular ejection fraction (LVEF) has assumed great significance in the era of automatic implantable cardioverter defibrillators (AICDs), and a low EF may be one of the sole deciding factor in determining AICD implantation in certain patient populations.
Aim: There are various methods, invasive and noninvasive, which can help calculate EF. We sought to conduct a retrospective study comparing EF estimation by invasive (angiography) and noninvasive methods [MUGA (multiple-gated acquisition), echocardiography (echo), single-photon emission computed tomography (SPECT)] in 5,558 patients in our hospital from 1995-2004.
Methods And Results: EF was estimated by > or = 1 method (angiography, MUGA, echo, SPECT) within a one-month period. Values for the four tests in 5,558 patients were as follows: angiography mean 46.2, range 20-75, standard deviation (SD) 13.1; MUGA mean 45.7, range 20-70, SD 11.6; echo mean 45.7, range 22-70, SD 11.2; and SPECT mean 54.4, range 30-75, SD 11.9. Excellent positive correlations were found among all four tests as follows: angiography and MUGA, correlation coefficient (r) = 0.97, angiography and echo r = 0.96, angiography and SPECT r = 0.94, MUGA and echo r = 0.97, MUGA and SPECT r = 0.94, and echo and SPECT r = 0.94. Values for SPECT were significantly higher than for angiography, echo and MUGA (p < 0.001). The arithmetic difference between angiography and MUGA (mean 0.50, range -5.0-5.0) and the arithmetic difference between angiography and echo (mean 0.52, range -5.0-15.0) were similar (p = 0.59). The arithmetic difference between SPECT and angiography (mean 8.2, range -15.0-20.0) was significantly larger than the arithmetic difference between angiography and echo (p < 0.001).
Conclusions: All the four methods used to estimate EF corelate well with each other. However, values estimated during stress testing by SPECT overestimate EF and are significantly higher as compared to MUGA, echo and angiography. Estimation of EF by MUGA, echo or angiography should be preferred over SPECT, especially when that patient warrants intervention. We conclude that the overestimation of EF by SPECT may deprive some deserving patients of the survival benefit afforded by ICD.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2574320 | PMC |
Asia Ocean J Nucl Med Biol
January 2023
Oncological and Radiological Sciences Cluster, Advanced Medical and Dental Institute, Universiti Sains Malaysia, Bertam, Penang, Malaysia.
Objectives: This study was undertaken to compare the correlation and agreement between Modified Simpson's method two-dimensional-echocardio-graphy (2D-echo) and rest multigated acquisition scan (MUGA) using both planar sodium iodide (pNaI) and cadmium-zinc-telluride (CZT) cameras to measure left ventricular ejection fraction (LVEF).
Methods: One hundred and nine breast cancer patients monitored for cardiotoxicity underwent 2D-echo, followed by pNaI and CZT MUGA scans on the same day. LVEF for CZT camera was processed using both automatic and manual processing methods, thus yielding four methods for the LVEF analysis.
Turk J Surg
December 2021
Department of General Surgery, Postgraduate Institute of Medical Education and Research (PGIMER), Chandigarh, India.
Objectives: Primary hyperparathyroidism (PHPT) is associated with increased cardiovascular morbidity and mortality with inconsistent results on the reversibility of cardiovascular changes after parathyroidectomy (PTx). The present study was undertaken to evaluate both structural and functional cardiac changes and their reversal after PTx in patients with PHPT.
Material And Methods: Thirty patients of symptomatic PHPT without cardiovascular risk factors were evaluated prospectively by means of 2D echocar- diography (ECHO) and Multigated Acquisition (MUGA) study before surgery and six months after curative parahyroidectomy.
Front Oncol
October 2019
Department of Radiation Oncology, Rutgers Cancer Institute of New Jersey, Rutgers University, New Brunswick, NJ, United States.
Radiotherapy for patients with non-metastatic human epidermal growth factor receptor 2 (HER2) positive breast cancer is commonly administered concurrently with adjuvant trastuzumab. However, there is limited data on the use of concurrent trastuzumab and hypofractionated radiotherapy (Hypo-RT), which is now standard of care for the majority of women receiving whole breast irradiation. In this study, we compared acute cardiotoxicity rates in HER2-positive breast cancer patients treated with concurrent trastuzumab and Hypo-RT or conventionally fractionated radiotherapy (Conv-RT).
View Article and Find Full Text PDFBreast Cancer Res Treat
April 2019
Department of Medicine, Dalhousie University, Halifax, NS, Canada.
Background: Cardiac assessment with multi-gated acquisition scan (MUGA) or echocardiography (ECHO) is commonly employed prior to adjuvant anthracycline-based chemotherapy (AA). However, the clinical utility of routine baseline cardiac assessments prior to AA for early-stage breast cancer (EBC) is unknown.
Objectives: To determine: (i) the clinical utility of routine baseline cardiac assessments prior to AA for EBC and (ii) identify patients in whom baseline cardiac assessments may not be warranted.
Curr Breast Cancer Rep
September 2017
Division of Oncology, Mayo Clinic.
Purpose Of Review: Treatment with trastuzumab is a cornerstone of human epidermal growth factor receptor 2 (HER2)-overexpressing breast cancer treatment, but carries an unfortunate risk of toxicity to the cardiovascular system. Here we review recent findings on trastuzumab-associated cardiotoxicity, focusing on its incidence, diagnosis, and treatment.
Recent Findings: Screening with multigated acquisition scan (MUGA) or echocardiogram (ECHO) is recommended to assess cardiac function prior to and during trastuzumab therapy.