Corrective osteotomy interventions on lower extremities are widely accepted procedures for restoring axial alignment of lower limbs. However, some studies reveal failure rates of up to 70 per cent in a 10 year time frame, which indicates that the success of corrective osteotomies depends on multiple factors. Based on a comprehensive review of error sources among conventional correction osteotomy interventions, a novel approach was developed in order to reduce these error sources among all clinical working steps (deformity determination, planning, and intra-operative realization). The article describes the implemented methodology for realizing optimal correction osteotomies based on a six-dimensional or 12-dimensional optimization module for single- and double-cut oblique osteotomies. The results show that the realized planning and navigation concept enables reduction in the error sources among the clinical working steps of correction osteotomy interventions.

Download full-text PDF

Source
http://dx.doi.org/10.1243/09544119JEIM276DOI Listing

Publication Analysis

Top Keywords

osteotomy interventions
12
error sources
12
single- double-cut
8
double-cut oblique
8
oblique osteotomies
8
correction osteotomy
8
sources clinical
8
clinical working
8
working steps
8
computer-assisted single-
4

Similar Publications

Effect of surgical treatment on relative tibial external rotation in patients with recurrent patellar dislocation.

Knee

December 2024

Graduate School of Guangzhou University of Chinese Medicine, Guangzhou, Guangdong, China; Second Affiliated Hospital of Guangzhou Medical University, Guangzhou, Guangdong, China. Electronic address:

Background: In the knee joints of patients with recurrent patellar dislocation (RPD), an increased relative tibial external rotation (rTER) is often observed. However, the changes in this parameter pre- and postoperatively remain unclear.

Purpose: The purpose of this study was to reveal preoperative and postoperative changes in rTER in patients with RPD.

View Article and Find Full Text PDF

Background: Distal tibial deformities are not assessed using the proximal anatomical axis (PAA) to determine the posterior tibial slope (PTS). Therefore, it seems advantageous to measure PTS on full-length lateral tibial radiographs using the mechanical axis (MA).

Purposes: To (1) compare the PTS measurements using the MA and the PAA and (2) determine whether using the PAA fails to detect a certain number of significantly elevated PTS values compared with using the MA.

View Article and Find Full Text PDF

Background: A larger joint line convergence angle (JLCA) increases the stress load on the medial compartment. Few reports, however, have discussed the effect of the JLCA on the cartilage status and clinical outcomes after opening-wedge high tibial osteotomy (OWHTO).

Purpose/hypothesis: To reveal the effect of the JLCA on clinical results after OWHTO.

View Article and Find Full Text PDF

Objective: The aim of this study was to establish a three-dimensional finite element (FE) hydraulic pressure technique model and compare the biomechanical characteristics of the osteotome technique and the hydraulic pressure technique using three-dimensional finite element analysis (FEA).

Methods: Three FE models were created: the hydraulic pressure technique (M1), the osteotome technique with a Ø 1.6-mm osteotome (M2), and the osteotome technique with a Ø 3.

View Article and Find Full Text PDF

Purpose: Hinge fractures show a relatively high incidence in varus and valgus distal femoral osteotomy (DFO) and can lead to delayed- or non-union. Another observed complication of a hinge fracture is an unintentional change of the postoperative femoral torsion of up to + 9.5° in conventionally performed DFO.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!