Background: Epidemiologic studies have demonstrated that elderly patients with fixed airflow obstruction can be affected by asthma or chronic obstructive pulmonary disease (COPD).

Methods: We studied 49 consecutive elderly outpatients, presenting fixed airflow obstruction, by clinical history (smoking), pulmonary function tests, blood gas analysis, and induced sputum.

Results: The age was not different in patients with COPD (n=28) and asthma (n=21) (70.2+/-3.9 years vs. 69.6+/-3.7 years), also the degree of fixed airflow obstruction was similar (FEV1: 58.3+/-1.5% vs. 59.0+/-1.4% of predicted). Patients with asthma had significantly more eosinophils in peripheral blood (0.43+/-0.05x10(-3)microL vs. 0.27+/-0.1x10(-3)microL, P<0.0001), and in induced sputum (5.0% [(p25th and p75th) 5.0-6.0%] vs. 1.0% [(p25th and p75th) 0.01-1.0%]; P<0.0001), as well as serum ECP (18.6+/-4.9ng/mL vs. 7.7+/-4.7ng/mL, P<0.0001) and ECP in the induced sputum (31.6+/-2.9ng/mL vs. 5.6+/-4.9ng/mL, P<0.0001). Finally, in induced sputum the eosinophils EG2+ were higher in patients with asthma than in patients with COPD (40.5 [(p25th and p75th) 39.3-44.3] MFI vs. 3.9 [(p25th and p75th) 0-11.4] MFI, P<0.0001). They also had significantly higher diffusing capacity, and a greater reversibility to steroids, after 14-day course of therapy, whereas the reversibility to 400microg of salbutamol was similar.

Conclusion: Despite similar fixed airflow obstruction, elderly patients with asthma have distinct characteristics compared with patients with COPD.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.rmed.2007.09.007DOI Listing

Publication Analysis

Top Keywords

fixed airflow
16
airflow obstruction
16
elderly patients
8
patients fixed
8
obstruction asthma
8
asthma chronic
8
chronic obstructive
8
obstructive pulmonary
8
pulmonary disease
8
similarity differences
4

Similar Publications

Background: NSAID-exacerbated respiratory disease (N-ERD) is a hypersensitivity to non-steroidal anti-inflammatory drugs (NSAIDs), such as aspirin or ibuprofen, accompanied by chronic rhinosinusitis (with or without nasal polyps) or asthma. The prevalence of hypersensitivity to NSAIDs is estimated to be 2%. The first line of treatment is the avoidance of NSAIDs.

View Article and Find Full Text PDF

Background and objective Applying different hygiene tools for implant maintenance alters surface configurations, impacting bacterial adhesion on titanium implant surfaces and potentially leading to peri-implant diseases. This study aimed to assess the alterations in surface topography of titanium implant fixtures after utilizing hygiene instruments such as airflow; erbium, chromium-doped: yttrium, scandium, gallium, and garnet (Er, Cr: YSGG) laser; and titanium brush, under scanning electron microscope (SEM) observation. Materials and methods We employed an experimental laboratory study design for this research, involving 20 MegaGen ST titanium implant fixtures (MegaGen Implant Co.

View Article and Find Full Text PDF

In industrial measurement, temperature field measurement typically relies on thermocouples and spectroscopic techniques. These traditional methods often suffer from insufficient precision, resulting in prevalent low-resolution measurements in real thermal scenarios. To address this challenge, we propose a novel general super-resolution approach for temperature field measurement in various thermal scenarios, leveraging the low-resolution (LR) data obtained from sensor array technology.

View Article and Find Full Text PDF

Fixed Airflow Obstruction in Asthma Can Be Identified Early by Low FEF25-75% and is Associated with Environmental Exposure.

J Asthma Allergy

October 2024

Department of Respiratory and Critical Care Medicine, Henan Provincial People's Hospital, Zhengzhou University People's Hospital, Henan University People's Hospital, Zhengzhou, Henan, People's Republic of China.

Purpose: This study aimed to identify environmental risk factors associated with asthmatic fixed airflow obstruction (FAO) and assess the relationship between small airway abnormalities defined by forced expiratory flow at 25-75% (FEF25-75%) and FAO.

Patients And Methods: We analyzed data from 312 han Chinese patients with stable asthma on standard treatment. Low FEF25-75% was defined as post-bronchodilator FEF25-75% z-score <-0.

View Article and Find Full Text PDF

Wearable Applicability of Respiratory Airflow Transducers: Current Approaches and Future Directions.

ACS Sens

November 2024

Shanghai Frontiers Science Research Base of Intelligent Optoelectronics and Perception, Institute of Optoelectronics, Fudan University, Shanghai 200438, People's Republic of China.

Advanced technologies employed in modern respiratory airflow transducers have exhibited powerful capabilities in accurately measuring respiratory flow under controlled and sedentary conditions, particularly in clinical settings. However, the wearable applicability of these transducers as face-mounted electronics for use in occupational and sporting activities remains unexplored. The present review addresses the critical wearability issue associated with current respiratory airflow transducers, including pneumotachographs, orifice flowmeters, turbine flowmeters, hot wire anemometers, ultrasound flowmeters, and piezoelectric airflow transducers.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!